3Montaudon M, Latrabe V, Pariente A, et al. Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions[J]. Eur Radiol, 2004,14:1234 - 1240.
3Covey AM, Gandhi R, Brody LA, et al. Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients. J Vasc Interv Radiol, 2004, 15(5): 479.?A
4Li H, Boiselle PM, Shepard JO, et al. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol, 1996, 167(1): 105.
5Tsukada H, Satou T, Twashima A, et al. Diagnostic accuracy of CT guided automated needle biopsy of lung nodules. AJR Am J Roentgenol, 2000, 175(1): 239.
6Ko JP, Shepard JO, Drucker EA, et al. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiol, 2001, 220(2): 554.
7Yeow KM, See LC, Lui KW, et al. Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol, 2001,12(11): 1305.?A?A
8Larscheid RC,Thorpe PE, Scott WJ, et al. Percutaneous transthoracic needle aspiration biopsy: a comprehensive review of its current role in the diagnosis and treatment of lung tumors [ J ]. Chest,1998,114( 3 ) :704-709.
9Zakowski MF. Fine needle aspiration cytology of tumor: diagnostic accuracy and potential pitfalls [ J ]. Cancer Invest, 1994,12 ( 5 ):505-510.
10Laurent F, Latrabe V, Vergier B, et al. Percutaneous CT guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technical aspiration and automated cutting[ J]. Cardiovasc Intervent Radiol, 2000,23(2) :266-272.?A?A
4Covey AM, Gandhi R, Brody LA, et al. Factors assoiated with pneumothorax and pneumothorax requiring treatment after perutaneous lung biopsy in 443 consecutive patients[ J]. J Vas In- terv Radio1,2004,15 ( 5 ) :479.
5Li H, Boiselle PM, Shepard JO, et al. Diagnostic accuracy and safety of CT guided percutanenus needle aspiration biopsy of the lung: comparison of small and large pumionary nodules [ J]. AIR Am J Roentgenol, 1996,167 ( 1 ) : 105.
6Webb W R, Muller N L, Naidich D P.高分辨率肺部 CT[M].潘纪戍,译.3版.北京:人民军医出版社,2007: 312-318.
7Mc Nulty W,Cox G,Au-Yong I.Investigating the solitary puimonary nodule[J].BMJ,2012,344:e2759.
8Webb W R.胸部影像学[M].2版.郭佑民,郭顺林,译.北京:科学出版社,2014:276.
9Chen Y R,Yeow K M,Lee J Y,et al.CT-guided hook wire localization of subpleural lung lesiona for video-assisted thoracoscopic surgery(VATS)[J].J Formos Med Assoc,2007,106:911.
10Pittet O,Christodoulou M,Pezzetta E,et al.Video-assisted t thoracoscopic resection of a small pulmonary nodule after computed tomography-guided localization with a Hook-wire system:experience in 45 consecutive patients[J].World J Surg,2007,31:575.