针对北京超高压公司运行的几例电容器漏油事故的统计,分析了锡焊套管与机械压接式套管的优缺点,并提出一些相应的改进措施,以供有关单位参考。
This paper gives some statistic about the oil leakage of power capacitors in Beijing Extra High Voltage Company, analyzes the advantage and the disadvantage of the tin weld bushing and mechanical pressed bushing of power capacitors. And gives some advice for relative companies about the improve measure.