期刊文献+

原发性开角型青光眼HRT视盘参数与视野缺损计分的关系 被引量:6

Correlation between optic disc parameters of HRT and visual field defect score in primary open angle glaucoma
暂未订购
导出
摘要 目的探讨原发性开角型青光眼(primary open an-gle glaucoma,POAG)病例的海德堡视网膜断层扫描仪(Hei-delberg retinal tomoscanner,HRT-Ⅱ)视盘参数与视野缺损计分的关系。方法对29例(30眼)POAG患者采用HRT-Ⅱ进行视盘检测;采用Humphrey视野计进行视野检查,运用AGIS计分系统并稍加改动对视野缺损情况进行计分,HRT参数包括视盘面积、视杯面积、盘沿面积、视杯容积、杯盘面积比、线性杯/盘比、平均视杯深度、视盘最大深度、平均视网膜神经纤维层厚度、视杯形态测量,将HRT视盘参数与视野计分进行相关统计学处理。结果HRT视盘参数中盘沿面积、视杯容积、杯盘面积比、平均视网膜神经纤维层厚度、视杯形态测量与视野缺损计分有直线相关关系。对视盘参数与视野计分进行逐步回归筛选变量时盘沿面积被选入,建立回归方程Y=12.351-5.123X(Y表示视野缺损计分,X表示盘沿面积)。结论POAG的视盘参数中盘沿面积与视野缺损计分关系最密切,视野缺损计分能对视野损害程度进行准确量化。 Objective To investigate the correlation between optic disc parameters of Heidelberg retinal tomoscanner(HRT-Ⅱ) and visual field defect score in patients with primary open angle glaucoma(POAG).Methods Thirty eyes of 29 cases with POAG were examined with optic disc by HRT-Ⅱ and visual field by Humphrey Field Analyzer.The parameters of HRT-Ⅱ included disk area,cup area,rim area,cup volume,cup/disk area ratio,linear cup/disk ratio,mean cup depth,maximum cup depth,mean retinal nerve fibre layer thickness and cup shape measure.These parameters were analyzed for the correlation with visual field defect score.Results There were linear correlation between rim area,cup volume,cup/disc area ratio,mean retinal nerve fibre layer thickness,cup shape measure and visual field defect score.Rim area was chosen at the regressive screening for optic disc parameters and visual field defeat score.The linear equation was Y=12.351-5.123X(Y means visual field defect score,X means rim area).Conclusion The correlation between rim area and visual field defect score is the closest relationship in all the parameters.Visual field defect score can quantify the visual field damage.
出处 《眼科新进展》 CAS 2008年第12期932-934,共3页 Recent Advances in Ophthalmology
关键词 原发性开角型青光眼 视盘 视野缺损计分 primary open angle glaucoma, optic disc, visual field defect score
  • 相关文献

参考文献4

二级参考文献26

  • 1刘杏,梁远波,凌运兰,黄晶晶,郑小平.视网膜断层扫描仪在青光眼性视神经病变中的诊断价值[J].中华眼科杂志,2004,40(11):737-740. 被引量:20
  • 2刘虎,陆莎莎,卞春及,袁孝如,朱承华.多焦视网膜电流图对开角型青光眼正常半侧视野的检测分析[J].眼科新进展,2005,25(2):146-148. 被引量:3
  • 3中华医学会眼科学会青光眼学组.原发性青光眼早期诊断的初步建议[J].中华眼科杂志,1987,23:127-127.
  • 4刘家琦 李凤鸣.实用眼科学(第2版)[M].北京:人民卫生出版社,2002.917.
  • 5李凤鸣.眼科全书[M].北京:人民卫生出版社,1996.2575.
  • 6Quigley HA, Addicks EM, Green WR. Optic nerve damage in human glaucoma. Arch Ophthalmol, 1982, 100:135-146.
  • 7Shields MB, Tiedeman JS, Miller KN, et al. Accuracy of topographic measurements with the Optic Nerve Head Analyzer. Am J Ophthalmol, 1989, 107:273-279.
  • 8Balazsi AG, Drance DB, Anderson M, et al. Neuroretinal rim area in suspected glaucoma and early chronic open- angle glaucoma.Correlation with parameters of visual function. Arch Ophthalmol,1984, 102:1011-1014.
  • 9Lee KH, Park KH, Kim DM, et al. Relationship between optic nerve head parameters of Heidelberg Retina Tomograph and visual field defects in primary open - angle glaucoma. Korean J Ophthalmol, 1996, 10:24-28.
  • 10Hood DC,Seiple W,Holopigian K,Greenstein V.A comparison of the components of the multifocal and full-fidld ERGs[J].Vis Neurosci 1997; 14:533-544.

共引文献23

同被引文献82

  • 1段宣初,吴勤,蒋幼芹,卿国平,江冰,石晶明.中央角膜厚度对压平眼压计测量值的影响[J].中国实用眼科杂志,2004,22(10):778-782. 被引量:13
  • 2杨蕾,严良,陆豪,丁琦,秦小玲.mfERG对原发性青光眼的诊断价值及其与视野视盘的相关性[J].眼科新进展,2005,25(6):543-546. 被引量:7
  • 3陆晨鸣,徐承慧,祝肇荣.倍频视野计检测青光眼性视野缺损能力的研究[J].眼科新进展,2006,26(12):927-929. 被引量:1
  • 4李凤鸣.实用眼科学.北京:人民卫生出版社,1997:1705.
  • 5Jonas JB, Stroux A, Vehen I, et al. Central corneal thickness correlated with glaucoma damage and rate of progression. Invest Ophthalmology Vis Sci 2005;46(4) :1269-1274
  • 6Gazzard G,Foster PJ,Viswanathan AC,et al . The severity and Spatial distribution of visual field defects in primary glaucoma : a eomparison of Primary Openangle glaucoma and primary angle-closure glaucoma.Arch Ophthalmol 2002 : 120( 12 ) : 1636-1643
  • 7Farrokh-siar L, Colev M, Arif A, et al . Central corneal thickness in normal,ocular hypertensive and primary open-angel glaucoma patients. Invest Ophthalmol Vis Sei 2004;45 :E-abstract 5563
  • 8Ehlers N, Bramsen T, Sperling S. Applanation tonometty and central corneal thickness.Aeta Ophthalmol 1975 ;53 ( 1 ) :34-43
  • 9Dohadwala AA, Munger R, Damji KF, et al . Positive correlation between Tono-Pen intraocular pressure and central corneal thickness. Ophthalmology 1998 ; 105 ( 10 ) : 1849-1854
  • 10Bechmann M, Thiel MJ, Roesen B, et al. Central corneal thickness determined with optical coherence tomography in various types of glaucoma. Br J Ophthalmol 2000 ;84 : 1233-1237

引证文献6

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部