摘要
针对137.5 MW机组保护系统频繁发生误动的现象,根据"二十五项反故障措施"的要求,对汽轮机危急保安系统的部分保护功能进行了优化,最大限度地防止了保护装置的误动和拒动。
Aiming at the misoperation phenomenon frequently encountered by the protection system of 137.5MW turbine unit, based on requirements of the "25 anti-failure measures", optimization is made for partial protection functions of the turbine emergency protection system ( manual/automatic protection logic), which prevents at most misoperation and non-operation of relevant protection devices.
出处
《发电设备》
2008年第6期542-545,共4页
Power Equipment
关键词
能源与动力工程
汽轮机
危急保安系统
保护逻辑
energy and power engineering
steam turbine
emergency protection system
protection logic