Daily QA 3在肿瘤放射物理技术质量保证中的使用及性能评价 被引量:5

Application and Function Evaluation of Daily QA 3 in Quality Assurance of Radiation Oncology Physics
暂未订购
导出
摘要 放射物理技术质量保证是肿瘤放射治疗质量保证中的一个重要方面。简述了DailyQA3日常质量保证仪的组成及工作原理,介绍了其在肿瘤放射物理技术质量保证中的使用方法和应用体会,并评价了其性能优缺点。总体来讲,Daily QA 3可以方便、快捷地满足日常的肿瘤放射物理技术质量,保证工作的需要。 The quality assurance of radiation oncology physics is one important aspect of QA in tumor radiotherapy. The constitution and work principle of Daily QA3 are briefly introduced. The practical application and experiences in quality assurance of radiation oncology physics are shared. The performance of function is evaluated. On the whole, Daily QA3 can be used conveniently to meet the need of the QA of radiation oncology physics.
作者 王洵 汪月莉
机构地区 宁波市第二医院
出处 《医疗卫生装备》 CAS 2008年第10期111-111,116,共2页 Chinese Medical Equipment Journal
关键词 DAILY QA3 肿瘤放射物理 质量保证 使用 性能 评价 Daily QA3 radiation oncology physics quality assurance application performance evaluation
  • 相关文献

参考文献4

二级参考文献28

  • 1IAEA. TRS277. Absorbed dose determination in photon and electron beams. Vienna: IAEA, 1997.
  • 2IAEA. TRS381. The use of plane parallel ionization chambers in high energy electron and photon beams. vienna: IAEA, 1997.
  • 3Suchowerska N, Da vison A, Drew J, et al. The validity of using radiographic film for radiotherapy dosimetry. Australas Phys Eng Sci Med,1997,20: 20-26.
  • 4Robar JL, Clark BG. The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry. Med Phys, 1999,26:2144-2150.
  • 5Evans MDC, Schreiner LJ. A simple technique for film dosimetry. Radiother Oncol, 1992,23: 265-267.
  • 6Childress NL, Dong L, Rosen Ⅱ. Rapid radiographic film calibration for IMRT verification using automated MLC fields. Med Phys, 2002, 29:2384-2390.
  • 7Olch AJ. Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance. Med Phys, 2002,29: 2159-2168.
  • 8Esthappan J, Mutic S, Harms WB, et al. Dosimetry of therapeutic photon beams using and extended dose range film. Med Phys,2002,29:2438-2445.
  • 9Williamson JF, Khan FM, Sharma SC. Film dosimetry of megavoltage photon beams: a practical method of isodensity-to-isodose curve conversion. Med Phys, 1981,8:94-98.
  • 10Kapulsky A, Mullokandov E, Gejerman G. An automated phantom-film QA procedure for intensity-modulated radiation therapy. Med Dosim,2002,27: 201-207.

共引文献20

同被引文献26

引证文献5

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部