期刊文献+

镍和氧化镍膜修饰的过氧化氢传感器的研究 被引量:4

Study of nickel and nickel oxide modified hydrogen peroxide electrochemical sensor
在线阅读 下载PDF
导出
摘要 该文研究了一种新的过氧化氢电化学传感器的制备方法。在含镍离子的溶液中用电化学方法在玻碳电极(GCE)表面修饰一层镍和氧化镍膜(Ni/Ni2O3),在一定电位条件下,该传感器能催化氧化过氧化氢,其响应电流与过氧化氢的浓度在1.5×10-7~3.8×10-3mol/L范围内呈线性关系。研究了各种实验条件对过氧化氢传感器性能的影响。该传感器制作简单,使用寿命长,在实际试样的回收率测定中,结果满意。 In this paper, a new method of the making electrochemical sensor for the determination of hydrogen peroxide. This sensor was fabricated by the means of electrodeposition nickel and nickel oxide on the glassy carbon electrode in the solution of Ni^2+. It was based on catalytic oxidation of H2O2 by nickel and nickel oxide under a certain applied potential. The response current was linear with the concentration of H2O2 range from 1.5 × 10^-7 to 3. 8×10^-3 mol/L. The effects of assay conditions on performances of hydrogen peroxide sensor were studied. The sensor was made simply and it can be used for a long time. The sensor had been used for the determination of real samples containing hydrogen peroxide with satisfactory recovery and result.
出处 《化学传感器》 CAS 2008年第3期28-32,共5页 Chemical Sensors
基金 国家自然科学基金资助项目(NO:20375034 20675071)
关键词 镍-氧化镍膜 循环伏安法 安培法 电化学沉积 nickel - nickel oxide film cyclic vohammetry amperometric electrodeposition
  • 相关文献

参考文献16

  • 1Yuan J C, Shi Her A M. Determination of subnanomolar levels of hydrogen peroxide in seawater by reagent - Injection chemiluminescence detection [J ]. Anal. Chem., 1999, 71:1 975 - 1 980.
  • 2Zhang L S, Wong G T F. Optimal conditions and sarnple storage for the determination of H2O2 in marine waters by the seopoletin - horseradish peroxidase fluorometrie method[J]. Talanta,1999, 48:1 031 -1 038.
  • 3Li Y Z. Townshend A. Evaluation of the adsorptive immobilisation of horseradish peroxidase on PTFE tubing in flow systems for hydrogen peroxide determination using fluorescence detection [ J ]. Anal. Chim. Acta, 1998,359 : 149 - 156.
  • 4Razola S S, Aktas E, Vire J C, et al. Geagentless enzyme electrode based on phenothiazine mediation of horseradish peroxidase for subnanomolar hydrogen peroxide determination[J]. Analyst, 2000, 125:79 - 85.
  • 5Lei C H, Zhang Z E, Liu H Y, et al. Biosensoring of hydrogen peroxide using new methylene blue incorporated in a montmorillonite-modified horseradish peroxidase immobilization matrix as an electron shuttle[J]. Anal. Chim. Acta, 1996, 332:73 - 81.
  • 6Yamamoto K, Ohgaru T, Torinura M, et al. Highly - sensitive flow injection determination of hydrogen peroxide with a peroxidase - immobilized electrode and its application to clinical chemistry[J]. Anal. Chim. Acta, 2000, 406:201 - 207.
  • 7Karyakin A A, Gitelmacher O V, Karyakin E E. Prussian blue-based first-generation biosensor: A sensitive amperometric electrode for glucose[J]. Anal. Chem., 1995, 67:2 419 - 2 423.
  • 8Kumar A, Malhotra R, Malhotra B D. Co - immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gelfilm[J]. Anal. Chim. Acta, 2000, 414:43 -50.
  • 9Chen L, Lin M, Hara M, et al. Kohlrabi - based amperometric biosensor for hydroger peroxide measurement [ J ]. Anal. Lett., 1991, 4:1 - 14.
  • 10Bogdanovskaya V A, Fridman V A, Tarasevich M R, et al. Bioelectrocatalysis by immobilized peroxidase the reaction mechanism and the possibility of electroanalytical detection of both inhibitors and actirators of enzyme. Anal[J]. Lett., 1994, 27:2 823 -2 847.

同被引文献52

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部