期刊文献+

HPLC法柱后衍生测定乳粉中牛磺酸含量不确定度评定 被引量:1

HPLC Method After-column Derivation Evaluation of uncertainty in determination of taurine in milk powder
在线阅读 下载PDF
导出
摘要 介绍HPLC法柱后衍生测定乳粉中牛磺酸含量的不确定度评定方法。从测量各步骤评定了不确定度的各项来源,对该方法所得分析结果的已识别来源的不确定度影响进行评价。并且可为实验室在该检测过程中进一步提高检测数据的可靠性和一致性作参考。 In this paper, the high performance liquid chromatography method after-column derivation is presented for the evaluation of uncertainty to determine taurine content of milk powder. Various sources of uncertainty from the determination procedure are assessed. The influence of the identified uncertainty of the analytical result is evaluated, and references for the reliability and consistency of the testing date in the laboratory are made.
出处 《生命科学仪器》 2008年第10期41-43,共3页 Life Science Instruments
关键词 牛磺酸 乳粉 HPLC法 柱后衍生 不确定度评定 taurine milk power high performance liquid chromatography after-column derivation Evaluation of uncertainty
  • 相关文献

参考文献1

二级参考文献3

  • 1JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 2GB/T5009.19-2003.食品中六六六、滴滴涕残留量的测定[S].[S].,..
  • 3中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2002..