西北地区特殊的气候条件下,依据室温条件的不同,夏季可采取的空气处理方案,有直接蒸发冷却、间接蒸发冷却和间接蒸发冷却与直接蒸发冷却相结合的二级蒸发冷却空气处理方案。通过对三种空气处理方案的过程、特点及原理的认真分析,并以兰州地区为例,比较三种方案的参数,确定出在西北地区夏季特殊气候条件下,最节能的空调方案及其适用性。
In the special climate conditions of northwest area, the air-conditioning processing plan can use the direct evaporating cooling, indirect evaporating cooling and indirect evaporating cooling and direct evaporating cooling unifies. Taking Lanzhou city as example, the parameters of the three processing were calculated, and the most economical air-condition system and its applicability was obtained.
出处
《建筑热能通风空调》
2008年第5期91-93,共3页
Building Energy & Environment
关键词
西北地区
环保节能
空调方案
蒸发冷却
Northwest area of China
environmental protecting and energy saving
air conditioning plan
direct evaporating cooling