期刊文献+

正畸力作用下微种植体支抗的应力分析 被引量:2

The Stress Analysis of Micro-implant with Orthodontic Force
在线阅读 下载PDF
导出
摘要 通过建立直径为1.4,1.6,1.8mm,长度为6,8,10mm,螺纹深度为0.2mm,螺纹间距0.5mm的Ti质微种植体支抗与颌骨有限元模型,研究在常用栽荷1.96N正畸力与微种植体长轴呈45°,60°和75°三种角度时的Ti质微种植体应力分布和大小。分析得出,应力主要集中在微种植体颈部1mm内,在其颈部1.2mm的范围内应力值的衰减都很明显,在颈部1.2mm的范围内曲线较陡。在设定的加载条件下,不同直径的微种植体应力值呈规则的变化趋势,直径1.8mm,45°时微种植体的各应力值极值最小。微种植体长度对应力的影响不大,位移变化均较小。 The stress distributions and values of the micro-implant are investigated in the study through modeling with different diameters ( 1. 4,1.6,1.8 mm), different length ( 6,8,10 mm) and different axis angles (45 °, 60°and 75°) with 1.96 N orthodontic force. The 3-dimesion finite element analysis shows that the stresses mainly center on micro-implant neck within 1 to 1.2 mm, and the stresses have nile changes with different diameters under loading. The diameter of 1.8 mm micro-implant has mini-stress distribution. The length of micro-implant screws has little influence on the stresses.
出处 《后勤工程学院学报》 2008年第4期96-99,共4页 Journal of Logistical Engineering University
关键词 正畸力 微种植体 几何模型 有限元 应力 orthodontic force micro-implant geometry model FEM stress
  • 相关文献

参考文献7

二级参考文献19

  • 1兰泽栋,林珠,龙红月,周磊.皮质骨厚度对支抗种植体-骨界面应力分布的影响[J].中国口腔种植学杂志,2004,9(2):54-57. 被引量:11
  • 2朱胜吉,周彦恒,傅民魁,丁鹏.应用种植体支抗正畸治疗的初步临床研究[J].口腔正畸学,2004,11(4):169-173. 被引量:49
  • 3叶德临,张尚慧,张建海,李光碧,杜传诗,赵云凤,魏治统,陈频.人牙本质泊松比的测定[J].生物医学工程学杂志,1995,12(1):10-13. 被引量:3
  • 4赖红昌,熊焕国,薛淼,杨宠莹,张保卫.不同长度种植体对骨界面应力影响的三维有限元分析[J].上海口腔医学,1997,6(1):20-22. 被引量:18
  • 5Park HS.A new protocol of the sliding mechanics with micro-implant anchorage (M.I.A)[J].Korea J Orthod,2000,30 (6) : 677-685.
  • 6Park HS.An anatomical study using CT images for the implantation of micro-implants[J].Korea J Orthod,2002,32(6): 435-441.
  • 7Miyawaki S, Koyama I, Inoue M, et al. Factors associated with the stability -of titanium screws placed in the posterior region for orthodontic anchorage [J]. Am J Orthod Dentofacial Orthop, 2003,124(4):373-378.
  • 8Park HS,Lee SK,Kwon OW. Group distal movement of teeth using microscrew implant anchorage [J]. Angle Orthod,2005,75:510-517.
  • 9Bae SM,Park HS,Kyung HM,et al.Clinical application of micro-implant anchorage.J Clin Orthod,2002,36(5):298-302.
  • 10Ciftci Y,Canay S.The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restorations.Int J Oral Maxillofac Implants,2000,15(4):571-82.

共引文献90

同被引文献49

  • 1于顺禄,白仁骁,郭若霖,王毅,孔德诚.骨重建过程“四环素活体标记”骨组织形态计量学指标在骨质疏松中的应用[J].中国体视学与图像分析,2003,8(2):119-123. 被引量:22
  • 2胡炜,傅民魁.口腔正畸治疗要点Ⅱ. 正畸治疗中的支抗与支抗控制[J].中华口腔医学杂志,2006,41(3):188-190. 被引量:20
  • 3Roberts WE,Smith RK,Zilberman Y,et al.Osseous adaptationto continuous loading of rigid endosseous implants[J].Am JOrthod,1984,86(2):95-111.
  • 4Chung K,Kim SH,Kook Y.C-orthodontic micro-implant fordistalization of mandibular dentition in Class III correction[J].Angle Orthod,2005,75(1):119-128.
  • 5Kanomi R.Mini-implant for orthodontic anchorage[J].J ClinOrthod,1997,31(11):763-767.
  • 6Wehrbein H,Glatzmaier J,Yildirim M.Orthodontic anchoragecapacity of short titanium screw implants in the maxilla.Anexperimental study in the dog[J].Clin Oral Implants Res,1997,8(2):131-141.
  • 7Saito S,Sugimoto N,Morohashi T,et al.Endosseous titaniumimplants as anchors for mesiodistal tooth movement in the beagledog[J].Am J Orthod Dentofacial Orthop,2000,118(6):601-607.
  • 8Schliephake H,Scharnweber D,Dard M,et al.Effect of RGDpeptide coating of titanium implants on periimplant boneformation in the alveolar crest.An experimental pilot study indogs[J].Clin Oral Implants Res,2002,13(3):312-319.
  • 9Geetha M,Singh AK,Asokamani R,et al.Ti based biomaterials,the ultimate choice for orthopae dic implants-A review[J].ProgMater Sci,2009,54(3):397-425.
  • 10Southard TE,Buckley MJ,Spivey JD,et al.Intrusion anchoragepotential of teeth versus rigid endosseous implants:A clinical andradiographic evaluation[J].Am J Orthod Dentofacial Orthop,1995,107(2):115-120.

引证文献2

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部