摘要
在抚顺乙烯装置碱洗塔的弱碱段投加国产 KD-1黄油抑制剂,考察了其抑制黄油生成的效果。通过1个月的连续观察,结果表明,投加 KD-1黄油抑制刑明显降低了碱洗系统各段碱液黄油含量和 COD 值,达到了抑制黄油生成的效果。排黄油量平均下降20%,碱洗塔压差保持了平稳、无波动,急冷水系统 pH 值无波动,保持平稳运行。
Grease inhibitor KD-1 was added to the Caustic Washing Tower in Fushun Ethylene Plant,and its effect of reducing the grease formed is investigated. The results show that grease inhibitor KD-1 remark- ably reduces the grease content in spent caustic and the COD value in waste water.The discharge of grease is lowered by 20% averagely,the pressure difference in caustic washing tower is stable,and no fluctuation is observed in the pH value in quench water system.A stable operation of the unit is achieved.
出处
《乙烯工业》
CAS
2008年第3期23-25,共3页
Ethylene Industry
关键词
黄油抑制剂
碱洗系统
乙烯装置
Grease inhibitor
Caustic washing system
Ethylene plant