摘要
采用网络等值法对复杂配电网进行可靠性评估。将配电网处理成图论中的有向图,用邻接矩阵描述配网拓扑结构,对系统进行分层处理,然后采用逆向与顺向宽度优先搜索实现逐层等效。通过实例计算验证了该算法的有效性。
A method of reliability-network-equivalent of complex distribution systems is used to calculate reliability indexes. The distribution network is regarded as a directed graph, so the topology of the network can he described by adja- cent matrix firstly. After the system is delaminated.the equivalent of the distribution network is performed one layer after another layer using upward and downward breadth first search method. The proposed method has been validated on a test system.
出处
《电气开关》
2008年第5期1-3,共3页
Electric Switchgear
关键词
配电网
可靠性评估
网络等值
分层
拓扑结构
distribution network
network equivalent
delamination
topology structure