期刊文献+

Ag/AgCl粉末电极和镀层电极在脑部EIT测量中的比较研究 被引量:2

Comparison of Performances of Ag/AgCl Coating Electrodes and Pulverized Electrodes in Cerebral Application of Electrical Impedance Tomography
暂未订购
导出
摘要 目的:针对一种新型的医用Ag/AgCl粉末电极和传统的医用Ag/AgCl镀层电极,比较两者在脑部电阻抗断层成像(Electrical Impedance Tomography,EIT)测量中的性能差异。方法:基于自行开发的EIT系统,分别利用Ag/AgCl粉末电极和镀层电极,分别对物理模型和人体对象进行脑部电阻抗断层成像测量,并且通过提出的两个指标(高频信噪比和低频信噪比)及接触阻抗来评价电极系统的特性。结果:相对于Ag/AgCl镀层电极,Ag/AgCl粉末电极具有更好的抗噪性和稳定性。结论:Ag/AgCl粉末电极能更有效地满足脑部EIT监护的要求。 Objective To compare the performance of novel Ag/AgCl pulverized electrodes with conventional Ag/AgCl coating electrodes in cerebral application of Electrical Impedance Tomography (EIT). Methods Based on the EIT system developed by our group, raw data were measured on a phantom and an adult volunteer, with Ag/AgCl coating electrodes and pulverized electrodes, respectively. The performances of electrode systems were evaluated in contact impedance and two other figures (the high-frequency SNR, HFSNR; the low-frequency SNR, LFSNR). Results Ag/AgCl pulverized electrode plays a better performance in resisting noise and keeping stabilization. Conclusion Ag/AgCl pulverized electrode develops the needs of imaging and monitoring human brains in EIT more availably.
出处 《医疗卫生装备》 CAS 2008年第9期7-11,共5页 Chinese Medical Equipment Journal
基金 国家自然科学基金重点项目(50337020) 国家重点支撑项目(2006BAI03A14)
关键词 Ag/AgCl粉末电极系统 电阻抗断层成像(EIT) 信噪比 Ag/AgCl pulverized electrode system electrical impedance tomography(EIT) signal-to-noise rate
  • 相关文献

参考文献8

  • 1Tidswell A T,Bagshaw A P,Holder D S. A comparison of headnet electrode arrays for electrical impedance tomography [J]. Physiol Meas. 2003.24 (2) : 527-544.
  • 2Tidswell A T,Gibson A,Bayford R H,et al. Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes[J]. Physiol Meas ,2001, 22( 1 ):167-175.
  • 3Fabrizi L,Sparkes M, Horesh L. Factors limiting the application of electrical impedance tomography for identification of regional conductivity changes using scalp electrodes during epileptic seizures in humans[J]. Physiol M eas, 2006,26 ( 5 ) : 163-174.
  • 4Brown B H. Electrical impedance tomography: a review [J]. J Med Eng & Tech,2003,27(3) :97-108.
  • 5McAdams E T,Jossinet J,Lackermeier A,et al. Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography[J]. Med& Biol Eng & Comput, 1996,34 (6) :397-408.
  • 6杨润楠,王聪,史学涛,董秀珍,尤富生.基于电阻抗断层成像的非均匀电导率颅骨物理模型研究[J].航天医学与医学工程,2007,20(2):133-135. 被引量:2
  • 7Ping Hua,Eung J W,Webster J G. Using compound electrodes in electrical impedance tomography[J]. IEEE Trans Biomed Eng, 1993, 40 ( 1 ) : 29-34.
  • 8李正,董秀珍,尤富生,赵大庆,林新,张国鹏,郑万松.电阻抗成像监护家兔腹内出血的实验研究[J].生物医学工程与临床,2006,10(1):5-8. 被引量:4

二级参考文献14

  • 1帅万钧,董秀珍,付峰.脑阻抗断层成像的图像重构算法[J].国外医学(生物医学工程分册),2004,27(6):332-336. 被引量:4
  • 2谈平原,周常亮,杨如高.交通事故所致肝外伤86例治疗分析[J].中国普通外科杂志,2005,14(2):154-155. 被引量:7
  • 3赵青川,李开宗,高志清,付由池,窦科峰.一种致腹部实质脏器闭合性创伤动物模型的简便小型撞击器[J].第四军医大学学报,1995,16(3):240-240. 被引量:4
  • 4Erenberg FG, Shim D, Beekman RH 3rd. Intraperitoneal hemorrhage associated with transhepatic cardiac catheterization:a report of two cases[J]. Cathet Cardiovasc Diagn, 1998,43(2):177-178.
  • 5Claus C, Majerus B. Acute hemoperitoneum caused by rupture of omentum adhesions after running[J]. Surg Endosc,2001,15(4): 413.
  • 6Gadallah MF,Torres-Rivera C, Ramdeen G, et al. Relationship between intrapetitoneal bleeding,adhesions,and peritoneal dialysis catheter failure:a method of prevention[J]. Adv Petit Dial, 2001,17 : 127-129.
  • 7Larson GM. Laparoscopy for abdominal emergencies[J].Scand J Gastroenterol Suppl, 1995,208:62-66.
  • 8Sadleir RJ,Fox RA. Detection and quantification of intraperitoneal fluid using electrical impedance tomography [J]. IEEE Trans Biomed Eng, 2001,48(4): 484-491.
  • 9Bagshaw AP,Liston AD,Bayford RH,et al.Electrical impedance tomo-graphy of human brain function using reco-nstruction algorithms based on the finite element method[J].Neuroimage,2003,20 (4):752-763.
  • 10Tidswell AT,Gibson A,Bayford,et al.Three dimensional electrical impedance tomography of human brain activity[J].NeuroImage,2001,13(2):283-294.

共引文献4

同被引文献12

  • 1尤富生,董秀珍,史学涛,付峰,刘锐岗,秦明新,汤孟兴,李江.电阻抗断层成像硬件系统的初步研究[J].中国体视学与图像分析,2003,8(2):114-118. 被引量:8
  • 2陈勇,徐桂芝,杨硕,杨庆新.经颅磁刺激线圈设计及分析[J].华北电力大学学报(自然科学版),2005,32(B12):98-101. 被引量:12
  • 3董秀珍.生物电阻抗技术研究进展.中同医学物理学杂志,:31-44.
  • 4Tidswell,A P Bagshaw,D S Holder. A comparison of headnet electrode arrays for electrical impedance tomography of the human head [J]. Physiol. Meas., 2003,24 : 527-544.
  • 5McAdams E T,Jossinet J, Lackermeier A and Risacher F.Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography[J]. Med. Biol. Eng. Comput., 1996,34:397- 408.
  • 6Boone K and Holder D .Effect of skin impedance on image quality and variability in electrical impedance tomography : a model study[J]. Med. Biol. Eng. Comput, 1996,36:351-354.
  • 7Mohamad Rahal,Joo Moy Khor. A comparison study of electrodes for neonate electrical impedance tomography[J]. Physiol. Meas.,2009,30 : 73-84.
  • 8白建新,程丽霞,史一明,王任鑫.基于针尖阵列的柔性干电极制备与测试[J].微纳电子技术,2019,56(1):57-64. 被引量:1
  • 9白洋,李小俚.经颅磁刺激-脑电成像系统[J].中国医疗设备,2015,30(12):5-9. 被引量:4
  • 10李江涛,郑敏军,曹辉.经颅磁刺激技术的研究进展[J].高电压技术,2016,42(4):1168-1178. 被引量:61

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部