期刊文献+

血管支架撑开均匀性问题的随机模型研究 被引量:1

RANDOMIZED MODEL OF EXPANSION UNIFORMITY OF INTRAVASCULAR STENT
暂未订购
导出
摘要 撑开均匀性是血管支架的一个重要力学性能,它对于筋的安全性有极大的影响作用.论文研究支架筋的宽度对于撑开均匀性影响规律.建立了基于串联模型的撑开均匀性力学模型;给出了激光切割过程中微管中心偏移量对于筋宽度的影响关系;建立了撑开均匀性随机分析的方法.论文组织了两个算例,详细说明了对该方法的应用,实现了激光偏心距发生随机变化时,对于血管支架撑开性能的随机分析. Expansion uniformity is an important mechanic property of intravascular stent,which pro- duce a critical effect on safety of the stent. The paper investigates mainly the regularity of expansion uni- formity affected by width of beam. The mechanical model has been set up on the basis of expansion uni- formity in unstable serial structure; the formula of the beam width on the condition of the offset is given in the process of laser cutting~ the method to analyze the stochastic problem is put forth. Two examples are organized to illustrate application of the methods,which analyse the stochastic properties of stents when offset of laser is happen.
出处 《固体力学学报》 CAS CSCD 北大核心 2008年第3期217-222,共6页 Chinese Journal of Solid Mechanics
基金 国家"973"计划项目(2005CB623904)资助
关键词 血管支架 均匀性 串联 随机 偏移量 intravascutar stent, uniformity, serial, randomization,offset
  • 相关文献

参考文献8

  • 1Dumoulin Cochelin B, Mechanical behaviour modelling of balloon-expandable stents [J]. Journal of Biomeehanics, 2000,33: 1461-1470.
  • 2Frederique E, Finet G, Boivin M, et al. Mechanical properties of coronary stents determined by using fi- nite element analysis [J]. Journal of Biomechanics, 2001,34: 1065-1075.
  • 3Awrejcewicz J, Wlodarczyk K, Ciach M. Finite Element Method Analysis of Non-Linear Behavior of Implants and Stents[C]. European Congress on Computational Methods in Applied Sciences, and Engineering, ECCOMAS, 2000.
  • 4Petrini L,Migliavacca F,Auricchio F,et al. Numerical investigation of the intravascular coronary stent flexiblity[J], Journal of Biomechanics, 2004,37 : 495-501.
  • 5杨杰,黄楠,杜全兴,张勇,陈虬.描述血管支架力学性能的新概念──形状系数[J].生物医学工程学杂志,2006,23(1):74-77. 被引量:10
  • 6Migliavacca F,Petrini L, Colombo M, et al. Mechanical behavior of coronary stents investigated through the finite element method[J]. Journal of Biomechanits, 2002,35: 803-811.
  • 7Lally C, Dolan F, Prendergast P J. Cardiovascular stent design and vessel stresses:a finite element analysis[J]. Journal of Biomechanics, 2005, 38: 1574- 1581.
  • 8Wang W Q,Liang D K,Yang D Z,et al. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method[J], Journal of Biomechanics, 2006,39 : 21-32.

二级参考文献8

  • 1Francesco Migliavaccaa, Lorenza Petrini, Valeria Montanari, et al. A predictive study of the mechanical behaviour of coronary stents by computer modeling. Medical Engineering & Physics,2005; 27:13.
  • 2David Chua SN, Mac Donald BJ, Hashmi MSJ. Finite element simulation of stent and balloon interaction. Journal of Materials Processing Technology, 2003;143: 591.
  • 3James E Moore, Joel L Berry. Fluid and solid mechanical implications of vascular stenting. Annals of Biomedical Engineering, 2002;30: 498.
  • 4Auricchio F, Di Loreto M, Sacco E. Finite-element analysis of a stenotic artery revascularization through a stent insertion. Comp Meth Biomech Biomed Eng, 2001; 4 : 249.
  • 5Dumoulin C, Cochelin B. Mechanical behaviour modelling of balloon-expandable stents, Journal of Biomechanics, 2000; 33: 1461.
  • 6王仁.塑性力学[M].北京:科学出版社,1998.46-57.
  • 7Francesco Migliavaccaa, Lorenza Petrinib, Maurizio Colombo,et al. Mechanical behavior of coronary stents investigated through the finite element method, Journal of Biomechanics,2002; 35 : 803.
  • 8Etave F, Finet G, Maurice Boivin, et al. Mechanical properties of coronary stents determined by using finite element analysis.Journal of Biomechanics,2001 ; 34:1065.

共引文献9

同被引文献18

  • 1王小平,焦延鹏,崔福斋.新型可降解金属血管支架的有限元力学分析[J].机械设计与研究,2007,23(5):59-61. 被引量:12
  • 2Heublein B, Rohde R, Kaese V, et al. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology[J]. Heart, 2003, 89(6):651-656.
  • 3Waksman R, Pakala R, Kuchulakanti P K, etal. Safety and efficacy of bioabsorbable magnesium alloy slcnts in porcine coronary arleries[J].Catheter Cardio vase Inter mcnt, 2006, 68(4):607-619.
  • 4Di Mario C, Griffiths H, Goktekin O, ct all. Drug-eluting bioabsorbable magnesium stent [J]. J Inrcrv Cardiol, 2004, 17(6) :391-395.
  • 5Maeng M, Jensen L O, Falk E, et al. Negative wtscular remodelling after implantation of bioabsorbable magnesi- um alloy stents in porcine coronary arteries: a random ised comparison with bare metal and sirolimus eluting stents[J]. Heart, 2009, 95(3):241- 216.
  • 6Erbel R, Di Mario C, Bartunek J, et al. Temporary scar folding of coronary arteries with absorbable magnesium stents: a prospective non randomized muiticentrc trial [J]. I.ancet, 2007, 369(9576):1869-1875.
  • 7郭飞飞.冠状动脉支架耦合变形过程有限元分析研究[D].呼和浩特:内蒙古工业大学,2012.
  • 8司超阳,王伟强,齐民.镁合金支架降解过程应力状态分析[OL].http://www.paper.edu.cn,2009-11-18.
  • 9David Chua S N, Mac Donald B J, Hashmi M SJ. Finite element simulation of slotted tube (stent) with the pres ence of plaque and artery by balloon expansion[J]. Jour- nal of Materials Processing Technology, 2004, 155 (156) :1772-1779.
  • 10Wang Weiqiang, Liang Dongke, Yang Dazhi, et al. Anal ysis of the transient expansion behavior and design opti mization of coronary stents by finite element method[J]. Journal of Biomechanics, 2006, 39(1) :21-32.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部