期刊文献+

电弧蒸发等离子体发射光谱分析法的研究 被引量:6

ARC VAPORIZATION PLASMA EMISSION SPECTROCHEMICAL DETERMINATION OF NIOBIUM,LEAD,TIN AND ZIRCONIUM
在线阅读 下载PDF
导出
摘要 本文介绍了采用自制电弧蒸发装置与ICP光源相接合,直接分析固体粉末样品的新方法。为了进一步提高分析的灵敏度与准确度,本方法应用了氯化物发生技术。通过对Sn、Pb、Nb、Zr四个选定元素的分析测试,考查了方法的可行性,四个元素的分析灵敏度为ppm级,十次测定的相对标准偏差(RSD)<8%。该方法装置简单、灵敏度高,预计可测试30余种元素。 A new method of are vaporization ICP-AES was described and the optimization of AVICP-AES operating conditions was studied by univariate searches of plasma power, vaporization current, vaporization time, and argon carrier flow rate. In order to improve further the sensitivity of determination and eliminate further the matrix effect a chloride generation-AES was used and Nb, Pb, Sn and Zr were determined by this method with a home-made apparatus.The sensitivities of Nb, Pb, Sn and Zr are 0.5ppm, 0.3ppm, 0.3ppm and 0.5ppm and the relative standard deviations are 4.2%, 4%, 7.8%, and 6.6% respectivety.
作者 马利 赵国生
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1989年第8期756-759,共4页 Chinese Journal of Analytical Chemistry
关键词 发射光谱 电弧蒸发 等离子体 Arc vaporization Induclively coupled plasma emission spectroscopy
  • 相关文献

参考文献2

  • 1陈寿根,光谱学与光谱分析,1985年,5卷,4期,60页
  • 2胡文范,分析化学,1981年,9卷,4期,466页

同被引文献1730

引证文献6

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部