期刊文献+

64层螺旋CT冠状动脉成像伪影产生原因分析 被引量:18

The analysis of artifacts in 64-slice spiral CT coronary angiography
原文传递
导出
摘要 目的探讨64层螺旋CT冠状动脉成像伪影产生的原因。方法100例临床怀疑或已确诊为冠心病的患者,以回颐性心电门控技术行64层螺旋CT冠状动脉平扫和增强扫描,后处理采用最大密度投影(MIP)、多平面重组(MPR)及容积再现技术(VRT),2名经验丰富的影像科医师分析冠状动脉成像伪影产生的原因,统计各类伪影占总伪影的比例。结果100例患者共显示冠状动脉节段1347段,其中存在伪影192段,发生率为14.2%。产生伪影的原因中最常见为呼吸运动,占64.6%(124/192);其次为心率快及心律不齐,占21.9%(42/192);而时相伪影占11.5%(22/192),对比剂及扫描参数伪影占2.1%(4/192)。结论呼吸运动、心率快及心律不齐、时相选择不当等会导致伪影,控制呼吸运动及心律不齐、降低心率、多时相重组,可以减少伪影产生及提高诊断准确率. Objective To investigate the reasons of artifacts in 64-slice spiral CT coronary angiography. Methods One hundred patients with diagnosed or suspected coronary artery disease underwent retrospectively ECG-gated 64-slice spiral CT coronary angiography. Maximum intensity projection (MIP) , muhiplanar reformation (MPR) and volume rendering technique (VRT) were reconstructed. The reasons of artifacts were assessed by two experienced radiologists. Results A total of 1347 segments ( 1347/1500, 89. 8% ) were reviewed ,the artifacts were found in 192 segments ( 14. 2% ). Breath movement was the most common artifact(124/192) , and the other reasons included fast rate and irregular rhythm of the heart beat (42/192) ,while the phase mismatch was the third reason(22/192). Conclusions The common artifacts of 64-slice spiral CT coronary angiography includes breath movement, fast rate and irregular rhythm of heart beat and phase mismatch. Breath-holding control, low rate and regular rhythm of heart beat, multiphase reconstruction are suggested for the accurate diagnosis.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2008年第9期923-926,共4页 Chinese Journal of Radiology
基金 深圳市福田区公益性科研项目资助(FTWS002)
关键词 冠状血管 伪迹 体层摄影术 X线计算机 Coronary vessels Artifacts Tomography, X-ray computed
  • 相关文献

参考文献6

二级参考文献36

共引文献143

同被引文献135

引证文献18

二级引证文献80

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部