期刊文献+

64层螺旋CT冠状动脉成像对左心室心肌密度差异的分析 被引量:5

Spatial heterogeneity of left ventricular myocardium attenuation during 64 multi-slice CT coronary artery angiography
原文传递
导出
摘要 目的分析64层螺旋CT(MSCT)冠状动脉CT血管成像(CTA)检查中,左心室心肌密度的特征性差异。方法行64层MSCT冠状动脉CTA检查的连续病例1130例中冠状动脉正常或狭窄程度〈25%的患者共119例。回顾性分析其CT增强扫描重建层厚3mm的横断面图像,选取主动脉瓣下缘平面左心室心肌为测量评价目标,在室间隔后部、前部、心尖、左心室游离壁前部及游离壁后部划5个兴趣区,分别测量其平均CT值,用配对t检验统计方法比较其差异。结果主动脉瓣下横断面图像中正常人左心室心肌密度值:室间隔后部、前部分别为(93.8±14.8)和(91.9±15.1)HU,心尖部为(69.9±15.5)HU,左心室侧壁前部、后部平均CT值分别为(79.7±16.9)和(88.0±14.3)HU,平均密度呈现为“U”字型。上述5个测量部位中,室间隔前部、后部测量值之间差异无统计学意义(t=0.968,P=0.3339),室间隔前部与心尖部、心尖部与左心室游离壁前部心肌密度差异具有统计学意义(t值分别为11.060和4.639,P值均〈0.01)。结论冠状动脉CTA检查中左心室心肌密度有差异,以心尖部最低,因此,依靠心肌低密度判断心肌梗死时要引起注意。 Objective To analyze the attenuation differences of left ventricular myocardium on 64-slice CT coronary artery angiography in adults. Methods Of 1130 consecutive patients, 119 patients (65 males, 54 females, ranged from 27 to 83 years with mean age of 52 years) with no stenosis or stenosis less than 25% in the left anterior descending arteries were enrolled. The standard axial image with 3 mm slice thickness just below the aorta valve was selected for measurement. The regions of interest (0. 1 cm × 0. 1 cm) in posterior interventricular septum (septal P) , anterior interventricular septum (septal A), apex, anterior free wall and posterior free wall of the left ventricle were selected within the myocardium and the mean CT value was measured. A paired Student t test was used for the comparison of CT values in different areas, P value under 0.05 was considered statistically significant. Results The mean attenuation of the apical region ( 69. 9 ± 15.5 ) HU was lower than that of septal A ( 91.9 ± 15.1 ) HU ( t = 11. 060, P 〈 0. 01 ) and anterior free wall (79. 7 ± 16. 9) HU ( t = 4. 639, P 〈 0. 01 ), the mean attenuation in septal ( 93.8 ± 14. 8) HU and posterior free wall ( 88.0 ± 14. 3 ) HU showed relatively higher values. The myocardial intensity attenuation presented as a U-shape in the left ventricular myoeardium. Conclusions The mean attenuation in the left ventricular myoeardium demonstrates as U-shape during the coronary artery angiography examination in normal adults. This can be helpful for judging the extent of myocardial infarction.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2008年第9期903-906,共4页 Chinese Journal of Radiology
关键词 冠状动脉疾病 体层摄影术 X线计算机 心血管造影 心肌 Coronary disease Tomagraphy, X-ray computed Angioeardiography Myoeardium
  • 相关文献

参考文献15

  • 1Chareonthaitawee P, Kaufmann PA, Rimoldi O, et al. Heterogeneity of resting and hyperemic myocardial blood flow in health humans. Cardiovasc Res,2001,50 : 151 - 161.
  • 2Franzen D, Conway RS, Zhang H, et al. Spatial heterogeneity of local blood flow and metabolite content in dog hearts. Am J Physiol, 1988,254(2 Pt 2) :H344-H353.
  • 3Marcus ML, Kerber RE, Ehrhardt JC, et al. Spatial and temporal heterogeneity of left ventricular perfusion in awake dogs. Am Heart J, 1977,94:748-754.
  • 4Deussen A. Blood flow heterogeneity in the heart. Basic ResCardiol, 1998,93:430-438.
  • 5Sanz J, Weeks D, Nikolaou K, et al. Detection of healed myocardial infarction with multidetector-row computed tomography and comparison with cardiac magnetic resonance delayed hyperenhancement. Am J Cardiol,2006,98 : 149-155.
  • 6Higgins CB, Siemers Fr, Schmidt W, et al. Evaluation of myocardial ischemie damage of various ages by computerized transmission tomography: time-dependent effects of contrast material. Circulation, 1979,60:284-291.
  • 7Doherty PW, Lipton M J, Beminger WH, et al. Detection and quantitation of myocardial infarction in vivo using transmission computed tomography. Circulation,1981,63:597-606.
  • 8Slutsky RA, Mattrey RF, Long SA, et al. In vivo estimation of myocardial infarct size and left ventricular function by prospectively gated computerized transmission tomography. Circulation, 1983, 67:759-765.
  • 9Nikolaou K, Knez A, Sagmeister S, et al. Assessment of myocardial infarctions using muhidetector-row computed tomography. J Comput Assist Tomogr,2004,28:286-292.
  • 10Hoffmann U, MiUea R, Enzweiler C, et al. Acute myocardial infarction: contrast-enhanced multi-detector row CT in a porcine model Radiology,2004,231:697-701.

同被引文献47

  • 1American Heart Association Writing Group on Myocardial Segmenta- tion and Registration for Cardiac Imaging. Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart:A Statement for Healthcare Professionals From the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association[J]. Circulation, 2002,105 : 539-542.
  • 2Marcus Carlsson,David Saloner,Alastair J,et al. Heterogeneous Microin- farcts Caused by Coronary Microemboli :Evaluation with Muhidetector CT and MR Imaging in a Swine Model[J]. Radiology,2010,254:718- 728.
  • 3Daniel C Paech,Adele R Weston. A systematic review of the clinical effectiveness of 64-slice or higher computed tomography angiography as an ahemative to invasive coronary angiography in the investigation of suspected coronary artery disease[J]. Bio Med Central Cardiovascu- lar Disorders ,2011,11:32.
  • 4Xinkai Qu,Weiyi Fang,Jianding Ye,et al. Acute and chronic in- farction in a pig model:Utility of multi-slice cardiac computed to- mography in assessing myardial viability and infarct parameters[J]. European Journal of Radiology, 2012,81 (4) : e431-437.
  • 5Wm. Guy Weigold MD,Suhny Abbara MD,Stephan Achenbach MD, et al. Standardized medical terminology for cardiac computed to- mography:A report of the Society of Cardiovascular Computed To- mography [J]. Journal of Cardiovascular Computed Tomography, 2011,5(3) : 136-144.
  • 6Patricia lozzo. Myocardial, Pefivascular,and Epieardial Fat [J] .Diabetes Care,2011,34 : s571 -s379.
  • 7George RT, Jerosch-Herold M, Silva C, et al. Quantifica- tion of myocardial perfusion using dynamic 64-detector computed tomography[J]. Invest Radiol, 2007, 42(12): 815- 822.
  • 8Nakauchi Y, Iwanaga Y, Ikuta S, et al. Quantitative myocar- dial perfusion analysis using multi-row detector CT in acute myocardial infarction[J]. Heart, 2012, 98(7): 566-572.
  • 9George RT, Arbab-Zadeh A, Miller JM, et al. Computed to-mography myocardial perfusion imaging with 320-row de- tector computed tomography accurately detects myocardi- al ischemia in patients with obstructive coronary artery disease[J]. Circ Cardiovasc imaging, 2012, 5(3): 333-340.
  • 10George RT, Arbab-Zadeh A, Miller JM, et al. Adenosine stress 64-and 256-row detector computed tomography angi- ography and perfusion imaging: A pilot study evaluating the transmural extent of perfusion abnormalities to predict ath- erosclerosis causing myocardial ischemia[J]. Circ Cardio- vasc Imaging, 2009, 2(3): 174-182.

引证文献5

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部