期刊文献+

PCM 对涤纶碱减量废水预处理的研究 被引量:7

STUDIES ON THE PRETREATMENT OF THE WASTEWATER FROM POLYESTER FABRIC PEELING WITH PCM
在线阅读 下载PDF
导出
摘要 对涤纶仿丝绸碱减量废水的预处理方法进行了研究。结果表明:采用复合无机盐PCM处理碱减量废水,处理效果优于FeSO4、PAC、Al2(SO4)3;当pH=11~12,投药量为1000mg/L时,COD去除率可达75%以上,达到了预处理要求。对PCM的主要作用机理也进行了初步探讨。 The pretreatment of wastewater from polyes ter fabric peeling for silk like effect has been studied,The experimental results show that the efficiency of inorganic salts compound PCM for alkali peeling wastewater was shown to be superior to FeSO 4、PAC、Al 2(SO 4) 3,When pH Value of wastewater is equal to 11~12,and the amount of PCM used is 1 000 mg/L,over 75% of COD may be removed and the aim of pretreatment can be abtained.The mechanism of PCM has also been investigated.
出处 《青岛大学学报(工程技术版)》 CAS 1997年第3期10-13,共4页 Journal of Qingdao University(Engineering & Technology Edition)
关键词 涤纶 PCM 碱减量 废水预处理 Alkali peeling Wastewater Pretreatment