烧结厂抽风机循环冷却水的水质稳定研究 被引量:1

A Study of the Stability in the Quality of Circulating Cooling Water from Suction Fan at the Sintering Plant of WISCO
在线阅读 下载PDF
导出
摘要 针对烧结厂抽风机循环冷却水的腐蚀、结垢问题,用稳定指数法、现场挂片监测及圬垢分析等手段对水质进行了分析评价,确定了处理配方,通过静态试验找出了配方中各药剂的最佳浓度配比,并用动态模拟试验进行了验证。 For the corrosion and scale of the circulating cooling water from suction fan at the Sintering Plant of Wuhan Iron & Steel Co.,the water quality is evaluated by means of the stability index technique,the monitoring of slice hanging on the spot and the analysis of fouling composition.The dispensation for the treatment of the water has been suggested.The optimum concentration ratio has been determined through static experiment.The result has been tested by the dynamic simulated experiment.
出处 《武汉冶金科技大学学报》 1997年第4期424-429,共6页
关键词 循环冷却水 腐蚀 结垢 抽风机 烧结厂 水质 circulating cooling water corrosion scale
  • 相关文献

参考文献4

  • 1杜忠明.碱性冷却水处理中的结垢控制[J]工业水处理,1988(04).
  • 2李裕芳.聚磷酸盐的水解和它的控制[J]工业水处理,1987(02).
  • 3姚广致,成荣钊.阻垢剂对碳酸钙垢的抑制能力[J]工业水处理,1986(04).
  • 4许保玖.给水处理[M]中国建筑工业出版社,1979.

同被引文献1

  • 1王大中.闭路循环冷却水处理[J]工业水处理,1985(04).

引证文献1