采用均匀设计法制备不同含量配比的安替比林、巴比妥、氨基比林校正集样品,用化学计量学方法---支持向量回归(SVR)方法建立校正模型,并对安替比林、巴比妥和氨基比林的模拟样品及安痛定注射液样品进行测定。结果表明,三种成分的加标回收率均在98%-104%之间,测定结果的相对标准偏差为0.48%-1.24%。
Support vector regression was applied to the simultaneous spectrophotometric determination of 3 components, i.e. phenazone, barbital and amidopyrine, in the anodyne "Antongding". A series of standard samples were prepared by the uniform designing with the 3 compounds mentioned above in different proportions. Calibration model was established by applying the support vector regression. As shown by the experimental results of analysis of simulated samples and substantial sample of "Antongding" injection, values of recovery and RSD's (n=5) found were in the range of 98%-104%, and in the range of 0. 48% to 1.24%, respectively,
出处
《理化检验(化学分册)》
CAS
CSCD
北大核心
2008年第8期742-745,共4页
Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词
分光光度法
支持向量回归
均匀设计法
多组分
同时测定
Spectrophotometry
Support vector regression
Uniform designing
Multi-components
Simultaneous determination