摘要 连续结合梁中负弯矩区混凝土桥面板会因承受较大拉应力而开裂,会引起钢筋及钢梁腐蚀等严重问题,影响结构的承载能力和耐久性。文章分析和介绍了对负弯矩区的一些处理方法,并指出了各种方法的优缺点。 Continuous composite beam in the negative moment area of concrete bridge decks bears more stress and brings cracking, these would cause serious problems such as the corrosion of steel and steel beam, and these affect the structure of the carrying capacity and durability. This paper analysed and presented some treatment methods about the negative moment area and pointed out the advantages and disadvantages of various methods.
作者 胡鹏飞
出处 《企业技术开发》 2008年第9期46-49,共4页 Technological Development of Enterprise
关键词 连续结合梁 负弯矩区 处理 预应力 continuous composite beam negative moment area treatment prestressing