期刊文献+

Z-plate钢板内固定治疗胸腰椎爆裂性骨折50例分析

Clinical alanyze of application of Z-plate anterior fixation system for 50 thoracolumbar fracture
暂未订购
导出
摘要 目的:评估Z-plate钢板治疗胸腰椎爆裂性骨折的效果。方法:50例胸腰椎爆裂性骨折前路减压、植骨融合、Z-plate钢板系统内固定。结果:4例失访,46例经4~36月随访,按Frankel功能分级:36例术前有神经症状者完全恢复正常,8例部分恢复,2例无任何恢复,无神经功能加重,所有患者无内固定物的松动断裂。结论:Z-plate钢板是一种疗效可靠的胸腰椎前路内固定系统,稳定性佳,操作安全,并发症少。 Objective:To evaluate clinical efficacy of Z-plate and indications for the anterior fixation system for thoracolumbar fracture. Methods:50 cases of thoracolumbar fracture underwent direct anterolateral decompression with sagittal reduction and corpectomy,antologous bone-grafting reconstruction and Z-plate fixation procedure. Results:4 cases were lost to follow-up,and 46 cases were followed up from 4 to 36 months.According to Frankel classification of neurologic deficit,36cases with neurologic deficits recovered completely;8 cases obtained a good functional outcome;2 case didn't recoved;No patient had neurologic deterioration after surgery Neither breakage of loosening of connections wac found, conclusion:Z-plate system is an effective ideal thoracoiumbar anternal fixation system. It has the advantages of reliable easy manipuplation,safety andless comlications.
出处 《重庆医科大学学报》 CAS CSCD 2008年第8期1016-1018,共3页 Journal of Chongqing Medical University
关键词 Z-PLATE钢板 胸腰椎爆裂性骨折 脊髓损伤 Z-plate system Thoracolumbar fracture Spinal cord injuries
  • 相关文献

参考文献2

二级参考文献40

  • 1James KS, Wenger KH, Schlegel JD et al.Biomechanical evalution of the stability of thoracolumbar burst fractures [ J ]. Spine,1994;19(15) :1731 - 1740.
  • 2Sjostrom L, Karlstrom G, Pech Pet al. Indirect spinal canal decompression in burst fractures treated with pedicle screw instrumentation[J]. Spine, 1996;21(1) :113-123.
  • 3Zou D, Yoo JU, Edwards WT et al. Mechanics of anatomic reduction of thoracolumbar burst fractures: comparison of distraction versus distraction plus lordosis in the anatomic reduction of the thoracolumbar burst fracture[J]. Spine, 1993; 18 (2) :195-203.
  • 4Muller U, Berlemann U, Sledge J et al.Treatment of thoracolumbar burst fractures without neurologic deficit by indirect reduction and posterior instrumentation: bisegmental stabilization with monosegmental fusion[J]. Eur Spine J, 1999;8(4) :284-289.
  • 5Alanay A, Acaroglu E, Yazici Met al.Short-segment pedicle instrumentation of thoracolumbar burst fractures: does transpedicular intracorporeal grafting prevent early failure[ J ]. Spine, 2001 ; 26 ( 2 ) : 213 -217.
  • 6Sanderson PL, Fraser RD, Hall DJ et al.Short segment fixation of thoracolumbar burst fractures without fusion [ J ]. Eur Spine J, 1999;8(6) :495 -500.
  • 7Diamond TH, Clark WA.Percutaneous vertebroplasty: a novel treatment for acute vertebral fractures [ J ].174(8) :398-400.
  • 8Mermelstein LE, McLain RF, Yerby SA.Reinforcement of thoracolumbar burst fractures with calcium phosphate cement, a biomechanical study [ J ]. Spine, 1998; 23(6) :664-671.
  • 9Verlaan JJ, van Helden WH, Oner FC et al. Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures [ J ]. Spine, 2002 ; 27 ( 5 ) :543- 548.
  • 10Scifert JL, Sairyo K, Goel VK et al. Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model[J]. Spine, 1999;24(21 ) :2206-2213.

共引文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部