摘要
与常规空调系统相比,水源热泵冰蓄冷系统初投资大,但其运行费用低于常规空调系统。本文针对某学术交流中心空调工程,提出了两种设计方案,通过分析与比较,表明将水源热泵冰蓄冷应用于该空调工程可取得较好的经济效益。
Compared with the general air-conditioning system,the water-source-heat-pumps combined ice storage system need more initial investment and little operation cost.Based on an air-conditioning project of an Academic Exchange Centre,two designs were brought forward and compared in detail.It shows that application of heat pump water with ice storage used in air-conditioning project has better economic benefits.
出处
《建筑热能通风空调》
2008年第3期36-38,56,共4页
Building Energy & Environment
基金
上海市自然科学基金资助项目(06ZR14040)
上海市教委科研项目(05FZ30)
上海海事大学重点学科建设项目(XL0103)
关键词
水源热泵
冰蓄冷
投资回收期
经济性
water-source-heat-pump
ice storage
investment recycle
economization