改进C-S模型用于含氢体系的气液平衡计算

Improvement of the C S Model for Vapor Liquid Equilibra Calculation in H 2 Hydrocarbon Mixtures
在线阅读 下载PDF
导出
摘要 利用ChaoSeader模型计算含氢体系气液平衡常数,计算结果在高压范围内普遍偏低,误差较大。提出了改进CS模型用于含氢体系气液平衡计算的两种方法。在进行模型改进时,选用了较典型的5个体系,168个实验点。用改进后的CS模型计算含氢体系的气液平衡,非氢组分的误差均比原模型的1135%低。在计算氢甲苯体系甲苯的气液平衡常数时,方法Ⅰ的平均误差为325%;方法Ⅱ的平均误差为570%。 The vapor liquid equilibra coefficients of H 2 hydrocarbon mixtures are calculated in Chao Seader model.Results show that the deviation is large at higher pressure range. Here are two different methods of improving C S model for calculating vapor liquid equilibra calculation of H 2 hydrocarbon mixtures from five typical systems and 168 data points. The average deviation of non hydrogen components of the improved C S models is smaller than the original deviation of 11.35%.The average deviation of improved model I is 3.25%,and improved model Ⅲ is 5.70% when using the improved models to calculate the K values in toluene of the H 2 toluene system.
作者 宋华 刘永莉
出处 《大庆石油学院学报》 CAS 北大核心 1997年第4期30-33,共4页 Journal of Daqing Petroleum Institute
关键词 含氢体系 气液平衡 C-S模型 烃类 石油 H 2 hydrocarbon systems, vapor liquilibra, model, improvement, deviation
  • 相关文献

参考文献3

  • 1白执松,石油及天然气物性预测,1995年,214页
  • 2Lin H M,J Chem Eng Data,1980年,25卷,252页
  • 3Chao K C,AIChE Jnal,1961年,7卷,4期,598页