摘要
理论推导了液态可燃物料生产场所火灾危险性类别判断中液态物料全部挥发后生成的液体蒸气体积计算公式,阐述了现行国家标准《建筑设计防火规范》有关条文说明中存在的问题,提出了该条文解释的修正意见,并对液态可燃物料生产场所火灾危险性类别的判断方法进行了举例说明。
The formula for volume of liquid vapor related to determining fire hazard rank of a work site with combustible liquid fuels is inferred theoretically. Some problems explanation concerned of Code of Design on Building Fire Prevention are interpreted. The revision opinion of the article explanation is proposed. The example on determining the fire hazard rank of a work site with combustible liquid fuels is given.
出处
《消防科学与技术》
CAS
2008年第7期497-498,505,共3页
Fire Science and Technology