摘要
本试验以Freon-113为工质,从试验和理论两方面研究了垂直布置倒U型管内汽液两相流的稳态、脉动曲线。试验范围如下:出口压力pe=0.2~0.4MPa,系统加热功率Q=6.4~10.4kW,质量流速m=3~24kg/min。理论研究采用一维均相模型,用差分法求解守恒方程组,得到稳态的流量——差压特性曲线,同时还采用数值计算方法模拟了压力降型脉动曲线。
With Freon-113 serving as a working medium the steady state and pulsation curves of steam/liquid dual phase flow in a vertically placed inverted U shaped tube is studied from both the experimental and theoretical aspects. The test range can be given as follows:outlet pressure P e=0.2-0.4 MPa, system heating power output Q=6.4-10.4 kW, mass flow speed m =3-24 kg/m. For the theroetical study adopted is a one dimensional uniform phase model with a difference method used for solving a group of conservation equations. Obtained are the steady state flow ratedifferential pressure characteristics curves. Moreover, a numerical calculation method has been used to simulate pressure drop type pulsation curves.
出处
《热能动力工程》
CAS
CSCD
北大核心
1997年第5期324-326,共3页
Journal of Engineering for Thermal Energy and Power