摘要
近年高压变频器在电厂的推广应用越来越广泛,考虑到电厂生产工艺对设备运行可靠性的要求非常高,重要辅机进行变频改造时一般都会要求配备工频旁路柜,对高压变频器工频旁路柜设计及继电保护配置整定的相关问题进行探讨。
In recent years, high-voltage power converter is in the promotion and application of increasingly widespread, the plant production process reliability of the equipment running is very high, important auxiliary to the general transformation will bypass with the frequency counter. The related issues of high voltage inverter frequency relay bypass counter design and configuration setting is discussed.
出处
《电气应用》
北大核心
2008年第13期33-39,共7页
Electrotechnical Application
关键词
高压变频器
工频旁路
继电保护
high-voltage converter the frequency of bypassroads relay