期刊文献+

用原子力显微镜观察汉坦病毒感染前后Vero-E6细胞的形貌变化 被引量:3

Apply AFM to observe the different cell surface between normal Vero-E6 cell and Vero-E6 cell contracted by Han taan virus
暂未订购
导出
摘要 目的用原子力显微镜(atom force microscope,AFM)观察汉坦病毒感染前后Vero-E6细胞的形貌变化。方法①用不同浓度的戊二醛固定细胞;②用不同稀释度的病毒感染细胞;③用同一稀释度的病毒分别感染细胞15、30、45、60、75、90分钟。结果①用0.5%和1.0%的戊二醛处理的细胞形态正常;用1.5%和2.0%的戊二醛固定的细胞表面凸凹不平孔洞较多,大部分细胞皱缩。②用不同稀释度的病毒感染过的Vero-E6细胞,与正常细胞相比,细胞表面粗糙,在细胞核周围有孔洞出现,但稀释度不同出现孔洞的数量也有差别,细胞表面光滑程度也有不同。③用同一稀释度的病毒感染细胞不同时间,发现细胞的形貌、表面粗糙度及细胞表面的孔洞数量都有了变化。结论用AFM技术可以观察到病毒感染前后细胞的超微结构,近似的反映出病毒感染细胞的动态过程。 Objective Apply AFM to observe the different cell surface between normal Veto-E6 cell and Vero-E6 cell contracted by Han taan virus. Methods ①Cells were treated with different concentration of glutaraldehyde;②Cells were treated with different dilution of Han taan virus ; ③Infect cells by the same dilution' s glutaraldehyde for 15,30,45,60,75, and 90 minutes respectively. Resuits ①Cells surface treated by 0.5% - 1.0% glutaraldehyde is normal, but the ones treated by 1.5% -2.0% glutaraldehyde have more protrusions and hollows, the majority of cells shrinkage; ②Veto-E6 cells surface infected by different dilution' s virus, compared with normal cells, is rougher and there are hollows arotmd nucleus, moreover, the hollow numbers and the smooth degree is also different as dilution concentration varying; ③The cell images, surface roughness, and hollow numbers also change when infected by the same dilution's virus for different time. Conclusion Applying AFM to observe cells can reveal the ultra micro-structure before and after cells are contracted by virus, reflect the dynamic process of virus infecting cells approximately.
出处 《中国实验诊断学》 2008年第5期598-601,共4页 Chinese Journal of Laboratory Diagnosis
关键词 原子力显微镜 汉坦病毒 VERO-E6细胞 AFM Han taan vims Vero-E6 cell
  • 相关文献

参考文献7

二级参考文献35

  • 1吴爱国,魏刚,李壮.原子力显微镜技术对生物样品的研究[J].分析化学,2004,32(11):1538-1543. 被引量:7
  • 2王莉娟,张英鸽,张飒,张德添.原子力显微镜对生理溶液中活细胞成像条件的研究[J].电子显微学报,2005,24(1):79-84. 被引量:5
  • 3王冰水,陈景藻,刘静,曾丽华,张飒.次声作用对CHO细胞膜的影响[J].中华物理医学与康复杂志,2005,27(3):156-158. 被引量:1
  • 4Xiao-LongJi,Ya-MinMa,TongYin,Ming-ShiShen,XinXu,WeiGuan.Application of atomic force microscopy in blood research[J].World Journal of Gastroenterology,2005,11(11):1709-1711. 被引量:1
  • 5[2]Wickenhauser C, Thiele J, Kummel T, et al. Hematopoietic stem cells of the human. Function and morphology[J]. Pathology, 1995,16(1): 1-10.
  • 6[4]Raffi S, Shapiro F, Pettengell R, et al. Human bone marrow microvessel endothelial cells support long-term proliferation and differentition ofmyeloid and megakaryocytic progenitors[J]. Blood, 1995,86(3): 3353-5.
  • 7[5]Binnig G, Quate CF, Gerber C. Atomic force microscope[J]. Phys Rev Lett, 1986, 56(9): 930-3.
  • 8CarlinFA(著) 孔庆雷(译).组织病理学及组织化学技术手册[M].北京:科学出版社,1982.33-41.
  • 9Santos Nuno C, Castanho Miguel ARB. An overview of the biophysical applications of atomic force microscopy.Biophysical Chemistry, 2004,107:133-149.
  • 10Doktycz M J, Sullivan C J, Hoyt PR, Pelletier DA, Wu S,Allison DP. AFM imaging of bacteria in liquid media immobilized on gelatin coated mica surfaces. Ultromicroscopy,2003,97:209-216.

共引文献36

同被引文献45

  • 1刘霓红,蔡红,李成,吴东来.狂犬病病毒不同毒株的形态学研究[J].电子显微学报,2006,25(2):178-181. 被引量:3
  • 2李庆虹,山丽梅,任永申.中药毒性研究进展[J].中华中医药杂志,2007,22(5):300-302. 被引量:20
  • 3Kuznetsov YG, Low A, Fan H, et al. Atomic force microscopy investigation of wild-type Moloney murine leukemia virus particles and virus particles lacking the envelope protein. Virology, 2004, 323(2) : 189-196.
  • 4Kienberger F, Zhu R, Moser R, eta|. Dynamic force microscopy for imaging of viruses under physiological conditions. Biol Proced Online, 2004, 6: 120-128.
  • 5Kuznetsov YG, Malkin AJ, Lucas RW, et al. Imaging of viruses by atomic force microscopy. J Gen Virol, 2001, 82( Pt 9) : 2025-2034.
  • 6Nettikadan SR, Johnson JC, Mosher C, et al. Virus particle detection by sohd phase immunocapture and atomic force microscopy. Biochem Biophys Res Commun, 2003, 311 (2) : 540-545.
  • 7King A, Crick L. Rabies-Related Virus. In : Rabies, Campbell JB, Charhon KM, eds. Kluwer Academic Publishers, 1988: 177- 199.
  • 8Gaudin Y, Ruigrok RW, Tuffereau C, et al. Rabies virus glycoprotein is a trimer. Virology, 1992, 187(2) : 627-632.
  • 9Trindade GS, Vilela JM, Ferreira JM, et al. Use of atomic force microscopy as a diagnostic tool to identify orthopoxvirus. J Virol Methods, 2007, 141 (2) : 198-204.
  • 10Kuznetsov YG, Victoria JG, Low A, et al. Atomic force microscopy imaging of retroviruses : human immunodeficiency virus and mu- fine leukemia virus. Scanning, 2004, 26(5) : 209-216.

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部