期刊文献+

正常拇指指尖三维运动定量分析 被引量:1

Three-dimensional quantitative analysis of the normal thumb tip motions
原文传递
导出
摘要 目的探讨一种新型的定量分析拇指指尖三维运动的方法,揭示拇指指尖的运动规律。方法应用三维运动分析系统的标志点放置于25名正常受试者拇指指尖和大多角骨上,固定腕关节和其他4指,拇指做最大和最小环转运动,记录运动中拇指指尖和大多角骨的三维空间坐标数据,重建拇指指尖最大工作空间,计算该最大运动空间体积。以上过程分三个不同测试日完成。结果重复实验的最大运动空间体积组间相关系数为0.902,变异系数为4.74%。平均拇指指尖工作空间体积男性组为131126.4mm^3,女性组为96414.16mm^3。回归分析方程男性组为V=0.0491^3+7.7061^2,女性组V=0.0521^3+7.2581^2。决定系数为0.98。结论应用三维运动分析系统测量拇指指尖运动是一种定量、精确、可行的方法。拇指总长立方与拇指腕掌关节工作空间体积存在线性回归关系。 Objective To explore a novel quantitative method which can be used to analyze diverse three-dimensional thumb tip motions. Methods Twenty-five normal subjects were enrolled in this ex- periment. The markers of the three-dimension motion analysis system were affixed to their thumb tips and trapezium bones. With the wrist and the other 4 fingers fixed, three-dimensional coordinates of the moving thumb tips and trapezium bones were recorded when the subjects were asked to actively execute maximal and minimal circumduction of the thumb tip. Maximal movements of the thumb tips were reconstructed to calculate their maximal volumes of workspace. All experiments were repeated in 3 separate testing days. Results In the test-retest, the interclass correlation coefficient and coefficient of variation of the volume of trapeziometacarpal (TMC) joint were 0.902 and 4. 74% respectively. The mean volume of the workspace of the thumb tip was 131126.4 mm^3 and 96414. 16 mm^3 respectively. Regressive function expressed V = 0.0491^3 + 7. 7061^2 for male groups, V=0.0521^3+7. 2581^2 for female groups, and determinate coefficient (R2) was 0.98. Conclusion It is quantitative, accurate, and feasible to measure thumb tip motion with this three-dimensional motion analysis system. Curve regressive relation exits between the volume of the workspace of the thumb tip and the total thumb length.
出处 《中华创伤骨科杂志》 CAS CSCD 2008年第3期266-269,共4页 Chinese Journal of Orthopaedic Trauma
关键词 拇指 关节 运动学 工作空间 Thumb Joint Kinetics Workspace
  • 相关文献

参考文献11

  • 1Engelberg AL. Hand function evaluation. In: American Medical Association. Guides to the evaluation of permanent impairment. 3rd ed. Chicago, IL: American Medical Association, 1988:678-679.
  • 2刘璠,王澍寰.国人手部测量正常值范围探讨[J].中华手外科杂志,1993,9(3):129-135. 被引量:13
  • 3Stfickland J. Results of flexor tendon surgery in zone Ⅱ. Hand Clin,1985, 1: 167-179.
  • 4Cooperman JM, Riddle DL, Rothstein JM. Reliability and validity of judgments of the integrity of the anterior cruciate ligament of the knee using the Lachman's test. Physical Therapy, 1990, 70: 225-233.
  • 5Kvalseth TO. Cautionary note about R2. The American Statistician, 1985, 39: 279-285.
  • 6Swanson AB, Hagert CG, Swanson GD. Evaluation of impairment of hand function. J Hand Surg(Am), 1983, 8: 709-722.
  • 7Su FC, Kuo LC, Chiu HY. Video-computer quantitative evaluation of thumb function using workspaee of the thumb. J Biomeeh, 2003, 36: 937-942.
  • 8Kuo LC, Cooney WP, Kaufman KR, et al. A quantitative method to measure maximal workspace of the trapeziometacarpal joint-normal model development. J Orthop Res, 2004, 22: 600-606.
  • 9Chiu HY, Lin SC, Su FC. The use of the motion analysis system for evaluation of loss movement in the finger. J Hand Surg(Br), 2000, 25: 195-199.
  • 10眭述平,曾炳芳,范存义,蔡培华,董扬,姜佩珠,于仲嘉.急诊拇指再造的适应证分析[J].中华创伤骨科杂志,2004,6(12):1334-1336. 被引量:13

二级参考文献31

  • 1Olsen I,Gebuhr P,Sonne Holm S.Silastic arthroplasty in rheumatoid MCP-joints.60 joints followed for 7 years.Acta Orthop Scand,1994,65:430-431.
  • 2Nalebuff EA.The rheumatoid hand:Reflections on metacarpophalangeal arthroplasty.Clin Orthop,1984,(182):150-159.
  • 3Beevers DJ,Seedhom BB.Metacarpophalangeal joint prostheses.A review of the clinical results of past and current designs.J Hand Surg(Br),1995,20:125-136.
  • 4Beevers DJ,Seedhom BB.Metacarpophalangeal joint prostheses:a review of past and current designs.Proc Inst Mech Eng,1993,207:195-206.
  • 5Moller K,Sollerman C,Geijier M,Branemark PI.Osseointegrated silicone implant.18 patients with 57 MCP joints followed for 2 years.Acta Orthop Scand,1999,70:109-115.
  • 6Vezina P,Gagnon S,Beaumont P,Page JM,Machuca C,Grenier N.Functional study of Swanson's metacarpophalangeal arthroplasties in rheumatoid arthritis.Ann Chir,1995,49:775-778.
  • 7Vermeiren JA,Dapper MM,Schoonhoven LA,Merx PW.Isoelastic arthroplasty of the metacarpophalangeal joints in rheumatoid arthritis:a preliminary report.J Hand Surg(Am),1994,19:319-324.
  • 8Sollerman CJ,Geijer M.Polyurethane versus silicone for endoprosthetic replacement of the metacarpophalangeal joints in rheumatoid arthritis.Scand J Plast Reconstr Surg Hand Surg,1996,30:145-150.
  • 9Schmidt K,Witt K,Ossowski A,Mienlke RK.Therapy of rheumatoid destruction of the middle finger metacarpophalangeal joint with a Swanson silastic implant stabilized resection arthroplasty:comparative study of long and intermediate term results with and without implantation of titanium grommets.Z Rheumatol,1997,56:287-297.
  • 10Varma SK,Milward TM.The Nicolle finger joint prosthesis:a reappraisal.J Hand Surg(Br),1991,16:187-190.

共引文献27

同被引文献4

引证文献1

相关作者