期刊文献+

MIPPO技术下LCP钢板治疗30例肱骨近端骨折的效果 被引量:4

Proximal humeral fracture of the 30 patients with locking proximal humeral plate treated by minimally invasive percutaneous plate osteosynthesis
暂未订购
导出
摘要 目的评价微创术式(MIPPO)技术下运用锁定加压钢板(LCP)治疗肱骨近端骨折的短期疗效。方法运用MIPPO技术结合LCP治疗的30例肱骨近端骨折患者进行回顾性分析。疗效评价采用NEER评分系统。结果术后30例患者均获得随访,随访时间为3-12个月,平均8个月,根据Neer评分,优良率为90%。结论MIPPO技术下运用LCP治疗肱骨近端骨折的短期疗效满意,这种手术方法具有切口美观,固定可靠,术中血运破坏少,出血量少,术后并发症少等优点,是治疗肱骨近端骨折的一种有效的方法。 Objective To evaluate the short -term results of minimally invasive percutaneous plate osteosynthesis for treating proximal humeral fracture in 30 patients with locking proximal humeral plate. Methods 30 patients with locking proximal humeral plate were treated minimally invasive percutaneous plate osteosynthesis with LCP under modified approach from Jan. All cases were followed - up with Neer scoring system. Results 30 patients were all followed up. The mean duration of following - up was 8 months, with the average from 3 to 12 months. According to Neer scoring, the excellent and good result rate was 90%. Conclusion LCP for proximal humeral fracture using minimally invasive percutaneous plate osteosynthesis treating shows good short term results. It is an effective method to treat proximal humeral fractures.
出处 《宁夏医学杂志》 CAS 2008年第3期228-230,I0001,共4页 Ningxia Medical Journal
关键词 MIPPO LCP 肱骨近端骨折 Minimally invasive percutaneous plate osteosynthesis Platefixation Proximal humeral fracture
  • 相关文献

参考文献11

  • 1张鹏翼,黄煌渊,陈文钧.肱骨近端骨折的手术治疗进展[J].上海医学,2004,27(12):946-948. 被引量:63
  • 2NeerCS. Displaced Proximal humeral fracture, part Ⅰ. Classification and evaluation [ J ]. J Bone Joint Surg(Am) , 1970,52 : 1077 - 1089.
  • 3Frigg R. Locking compression plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator( PC-Fix) [J]. Injury, 2001, 32 (Suppl) : 63-66.
  • 4侯之启,陈铭,戈涛,邝炯祥,徐中和.MIPPO技术LCP钢板内固定治疗老年肱骨近端骨折[J].骨与关节损伤杂志,2004,19(11):736-738. 被引量:42
  • 5王亦璁.骨折治疗的微创术式[J].中华骨科杂志,2002,22(3):190-192. 被引量:208
  • 6Lill H, Hepp P, Rose T, et al. The angle stable locking proximal-humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-Splitting approach-technique and first results [ J ]. Zentralbl C hir, 2004,129:43 - 48.
  • 7Krettek C, Schandelmaier P, Miclau T, et al. Minimally invasive percutaneous plate asteosynlhesis(MIPPO) using the DCS in proximal and distalfemoralfracture [ J ]. Injury, 1997,28 (Suppl) :20 - 30.
  • 8S Arens, C Kraft U, Schlegal. Susceptibility to local infection in biological internal fixation: experirmental study of open vs invasive plate osteosynthesis in rabbit[J].J Arch Trauma Surg, 1999,119 : 82 - 85.
  • 9Michael leanig, Ralph hertel. The evolution of indirect reduction techniques on the treatment of fractures [ J]. J Clin Orthop, 2000, 375:7 - 14.
  • 10陆晴友,王秋根,张秋林,唐昊,吴剑宏,王万宗.肱骨近端骨折的手术治疗[J].中华创伤骨科杂志,2003,5(4):316-319. 被引量:84

二级参考文献53

  • 1Sommer C, Gautier E, Muller M, et al. First clinical results of the locking compression plate (LCP). Injury, 2003, 34 (2): 43
  • 2Wagner M. General principles for the clinical use of the LCP. Injury, 2003, 34 (2): 31
  • 3Farouk O, Krettek C, Miclau T, et al. Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique? J Orthop Trauma, 2002, 14:225
  • 4Krettek C, Schandelmajer P, Miclau T, et al. Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury, 1997, 28 (1): 20
  • 5Helfet DL, Shannard PY, Levine D, et al. Minimally invasive percutaneous plate osteosynthesis (MIPPO) of fracture of the tibia. Injury, 1997, 28 (1): 42
  • 6Krettek C, Schandelmaier P, Tscherne H.Nonreamed interlocking nailing of closed tibial fractures with severe soft tissue injury.Clin Orthop, 1995, (315): 34-47.
  • 7Gregory P, Sanders R. The treatment of closed, unstable tibial shaft fractures with unreamed interlocking nails. Clin Orthop,1995, (315): 48 -55.
  • 8Blachut PA, Meek RN, O'Brien PJ. External fixation and delayed intramedullary nailing of open fractures of the tibial shaft: a sequential protocol. J Bone Joint Surg(Am), 1990,72:729 -735.
  • 9Mayr E, Braun W, Ruter A. Can unreamed tibial nailing replace external fixators in management of open tibial fractures?Chirurg, 1994, 65: 983-987.
  • 10Palmer RH. Biological osteosynthesis. Vet Clin North Am Small Anim Pract, 1999, 29:1171 - 1185.

共引文献382

同被引文献19

  • 1侯之启,陈铭,戈涛,邝炯祥,徐中和.MIPPO技术LCP钢板内固定治疗老年肱骨近端骨折[J].骨与关节损伤杂志,2004,19(11):736-738. 被引量:42
  • 2张鹏翼,黄煌渊,陈文钧.肱骨近端骨折的手术治疗进展[J].上海医学,2004,27(12):946-948. 被引量:63
  • 3荣国威,王承武.骨折.人民卫生出版社,2005:543.
  • 4Frigg R.Locking compression plate(LCP),An osteosynthesis plate based on the Dynamic Compreession Plate and the Point Contact Fixator(PC-Fix)[J].Injury,2001,32(Suppl):63-66 3.
  • 5Wagner M.General,principles for the clinical use of the LCP[J].Injury,2003,34(2):314.
  • 6Neer CS.Displaced Proximal humeral fracture part I Classification and evaluation[J].J Bone Joint Surg(Am),1970,52:1077-1089.
  • 7Gallo RA,Zeiders GJ,Altman GT.Twoincision technique for treatment of complex proximal humerus fractures[J].Orthop Trauma,2005,19(10):734-7407.
  • 8Kenneth A,Erik N,Eric F.Biomechanics of locked plates and screws[J].J Orthop Trauma,2004,18:488.
  • 9Frigg R.Locking compression plate(LCP).An osteosynthesis plate based on the dynamic compression plate and the point contact fixator(PC-Fix)[J].Injury,2001,32(Suppl 2):63-66.
  • 10Frigg R. Loc kingcompressionpl a t e (LCP), A nosteosynthesis plate based on the Dynamic Compreession Plate and the Point Contact Fixator( PC -Fix) [ J ]. Injury ,2001 ;32 (Suppl) : 63 - 66.

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部