期刊文献+

64层螺旋CT冠状动脉成像伪影产生及解决对策 被引量:20

The Reason and Strategy of Artifact of Coronary Artery Imaging with 64-slice Spiral Computed Tomography
暂未订购
导出
摘要 目的探讨64层螺旋CT冠状动脉成像伪影产生的原因及处理对策。方法1000例临床怀疑或者已确诊为冠心病的患者,以回顾性心电门控技术行64层螺旋CT冠状动脉平扫和增强扫描,后处理行MIP、MPR及VRT重建,由两名经验丰富的影像科医生对冠状动脉伪影进行评估。结果1000例患者共显示冠状动脉节段13470段,其中存在伪影的有1920段,占14.25%,大部分为轻度伪影,发生率为13.65%,中重度伪影发生率为0.60%。产生伪影的原因中最常见的为呼吸运动,占总伪影发生率的70.77%,其次为心率,占总伪影发生率的10.77%。结论冠状动脉伪影产生的原因如下:呼吸运动、心率、心律变化、造影剂浓度、重建时相等。控制呼吸运动及心律不齐、降低心率、多时相重建等可以减少伪影产生及提高诊断准确率。 Objective To investigate the reason and strategy of artifact of coronary artery imaging with 64-slice spiral CT. Methods 1000 patients with diagnostic or suspected coronary artery disease underwent retrospectively ECG-gated 64-slice spiral CT. Images were reconstructed under different reformations of MPR, MIP and VRT. Image quality was assessed by two experienced radiologist. Results A total 13470 of 15000(89.80%) segments were visualized,the artifact segments were 1920,the incidence was 14.25%,the incidence of lower grade artifact was 13.65%, medium and heavy incidence added up to 0.60%. Breath movement caused most artifact,the other reason was heart rate. Conclusion The reason of artifact includes:breath,speed of heart, rhythm of heart, contrast concentration, rebuild percent and so on. Hold-breath and inhibit irregularity heart rhythmn,low-heart-rate,more rebuild percent lead to accurate diagnosis.
出处 《中国现代医生》 2008年第6期6-8,F0003,共4页 China Modern Doctor
基金 深圳市福田区公益性科研项目(编号:FTWS002)
关键词 冠状动脉 伪影 X线计算机断层摄影术 呼吸 心律 Coronary artery Artifact Computed Tomography Breath Rhythm of the heart
  • 相关文献

参考文献8

  • 1张兆琪,马晓海.64层螺旋CT冠状动脉成像——无创性冠状动脉检查的新纪元[J].中华放射学杂志,2006,40(8):789-791. 被引量:88
  • 2[2]Hong C,Becker CR,Huber,et al.ECG-gated reconstructed mul-ti-detector row CT Coronary angiography:effect of varying trigger de-lay on image quality[J].Radiology,2001,220(3):712-717.
  • 3[3]American heart association Committee Report.A reporting system on patients evaluated for Coronary artery disease[J].Circulation,1999,5l(1):7.
  • 4[5]Giesler T,Baum V,Ropers D,et al.Nonivasive visualization of coronary arteries using contrast enhanced multidetector Ct:influenee of rate on image quality and stenosis detection[J].AJR,2002,179(1):911-916.
  • 5朱海峰,范家栋,郑卓肇,何汇忱,舒邦明.16层螺旋CT冠状动脉成像初步探讨[J].中华放射学杂志,2006,40(10):1064-1068. 被引量:24
  • 6刘斌,赵红,吴兴旺,张家文,余永强,廖静敏.64层螺旋CT冠状动脉成像图像质量的相关影响因素分析(心脏体模模拟实验)[J].中华放射学杂志,2006,40(9):980-983. 被引量:38
  • 7[8]Shimss,Kim Y,Lim SM,et al.Improvement of image quality with beta-blocker premedieation on ECG-gated 16-MDCT coronary an-giographp[J].AJR AmJ Roentgenol,2005,184(2):649-654.
  • 8[10]Dewey M,Hoffmann H,Hamm B,et al.Multislice CT coronary angiography:effect of sublingual nitroglycerine on the diameter of coronary arteries[J].Rofo,2006,178(1):600-604.

二级参考文献33

共引文献140

同被引文献130

引证文献20

二级引证文献79

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部