摘要
记录70例冠心病人经皮冠状动脉腔内成形术(PTCA)时体表(S-ECG)和冠脉内心电图(IC-ECG)发现,随球囊充盈次数增加,ST段抬高幅度减低,心绞痛出现时间延长,最大QT间期缩短及QT离散度和JT离散度减低,提示PTCA时多次短暂心肌缺血可能由于缺血预适应而诱发心肌内在的抗心律失常保护作用。
Both body surface (S-ECG) and intracoronary electrocardio grams(IC-ECG) were recorded during percutaneous transluminal coronary angioplasty (PTCA) in 70 patients with coronary artery disease.During multiple balloon inflations,the magnitude of ST segment elevation was reduced.The QT interval,QT and JT dispersion were increased during initial two balloon inflations and decreased progressively during the following balloon inflations.The study suggests that multiple transient myocardial ischemia during PTCA may induce myocardial ischemic preconditioning which may have protective antiarrhythmic effects.
出处
《临床心电学杂志》
1997年第4期147-149,共3页
Journal of Clinical Electrocardiology
关键词
PTCA
心电描记
心肌缺血
QT离散度
S-ECG
percutaneous transluminal angioplasty,coronary vessels
electrocardiography
myocardial ischemia
QT dispersion