摘要 目的根据对血细胞分析仪检测结果的分析及细胞形态学的鉴别,建立显微镜复检标准,保证血细胞分析结果的准确性。方法根据本院门诊病人的具体情况应用血细胞分析仪检测结果筛选制定出显微镜复检标准,通过对1683例标本仪器结果的数据分析,对标准的可行性和实用性进行探讨与分析。结果仪器检测的标本有16.1%的血液分析标本需要复查,其中18.5%存在中性杆状粒细胞增多、异型淋巴增多、幼稚细胞、中晚幼粒细胞、靶形红细胞等其他类型的异常,所制定的标准经临床验证有重要价值和意义。结论血细胞分析仪不能完全代替显微镜涂片检查,制定血细胞显微镜复检标准非常必要,保证血细胞检查的准确性,为临床诊断、治疗提供有价值的信息。 Objective To establish a criteria for accurate results on complete blood counts (CBC) by means of automatic hematology analyzer analysis and cell morphological discrimination. Methods Based on the personal information of outpatients from automatic hematology analyzer, we set up criteria for blood cell microscopic reexamination. The feasibility and practicality of the criteria were discussed and evaluated by the examination of 1 683 blood specimens. Results 16.1% of CBC specimens needed for microscopic reexamination, of which 18.5% had increased bands or increased atypical lymphocytes or acanthocytes or target cells or other abnormalities. The criteria might help to find more abnormal cells; it could provide more accurate and reliable information to clinical doctors. Conclusion Automatic hematology analyzer can't take the place of microscopic examination fully. It is very important to set up the criteria for performing peripheral blood smear. It may guarantee the accuracy of CBC results and provide some important information for clinical diagnosis and proper treatment.
出处 《检验医学与临床》 CAS 2008年第6期340-341,共2页 Laboratory Medicine and Clinic
关键词 血细胞 血细胞分析仪 显微镜检查 标准 blood cells hematology analyzer microscopic examination criteria
  • 相关文献

参考文献7

二级参考文献19

  • 1本刊编辑部,丛玉隆,李艳,袁桂清.加强形态学临床检验专家座谈会纪要[J].中华检验医学杂志,2005,28(2):147-148. 被引量:63
  • 2Goossens W, Van Hove L, Verwighen R L. Monocyte counting: Discrepancies in results obtained with different automated instruments[J] .J Clin Pathol, 1991,44(3) :224-227.
  • 3NCCLS Decument. GP16-A: Urinalysis and collection, transportation, and preservation of urine specimens [ J ]. Approved guideline, 1995, (15): 15.
  • 4Robertson EP, Lai HW, Wei KD. An evaluation of leukocyte analysis on the Coulter STKS. CIin Lab Haexnat, 1992, 14:53-68.
  • 5Michael WS. The atypical lymphocyte. International Pediatrics,2003,18:10-22.
  • 6Pierre BY. Peripheral blood fdm review, the demise of the eyecount leukocyte differential. Clin Lab Med, 2002,22:279-296.
  • 7Westgard JM, Klee GG.Quality management. In: Clinical Diagnosis and Management by Laboratory Methods, edited by Henry JB,19th edition. New York, John Wiley & Sons,1998.384-419.
  • 8NCCLS. Method comparison and bias estimation using patient samples; Approved guideline (2nd edition);National Committee for Clinical Laboratory Standards, Villanova, PA; 2002,EP9-A2.
  • 9NCCLS. Calibration and quality control of automated hematology analyzer; Aproved guideline; National Committee for Clinical Laboratory Standards, Villanova, PA; 1999,H38-P.
  • 10NCCLS. Reference leukocyte differential count (proportional) and evaluation of instrument methods. Approved Standard, H20-A. Villanova, PA,1992.

共引文献388

同被引文献23

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部