摘要 目的探讨改善64层螺旋CT冠状动脉图像质量的条件。方法在不同的心率、不同重组算法、图像重组相位窗下,用心脏冠状动脉模具评价64层螺旋CT冠状动脉图像质量。结果心率小于70次/分,心率波动范围小于10次/分时图像质量最佳;图像质量在R-R间期的75%相位(舒张中期)最好;实验数据共108组,采用单扇区、双扇区、四扇区重组成功率分别为93.5%,91.6%,93.4%,组间差异无统计学意义(χ2=4.163,P=0.125)。优良率分别为81.8%,79.2%和84.1%。结论心率、重组算法和图像重组相位窗是影响多层螺旋CT冠状动脉成像的主要参数,运用合适参数能获得更优质图像。 Objectives To improve the image quality of 64-detector CT coronary artery angiography, and the value in evaluating the lesions of coronary artery through coronary artery phantom experiment. Methods The image quality of 64-detector CT coronary artery angiography with different heart rate, reconstruction algorithm and different phase were evaluated. Results The best image quality was got during heart rate less than 70 beats/ min, fluctuation less than 10 beats/min, and at 75% R-R interval. The reconstruction rates with segment, burst and plus algorithm were 93.5%, 91.6% and 93.4%, respectively, and no statistical difference amount groups was found (X^2=4.163, P=0.125). The best image quality rates reached 81.8%, 79.2% and 84.1%, respectively, and were no difference between burst and plus algorithm (P=0.004). Conclusions Heart rate, reconstruction algorithm, reconstruction phase time are the main parameters affecting image quality of multidetector CT coronary artery angiography, high-grade image can be gotten by regulating the parameters.
出处 《岭南心血管病杂志》 2008年第1期56-58,共3页 South China Journal of Cardiovascular Diseases
基金 广东省医学科研基金(A2006030) 广东省科技攻关项目(2006B36030026) 广州市科技攻关项目(2006Z3-E0241)
关键词 计算机断层扫描 冠状动脉 图像 心率 spiral CT coronary artery image quality heart rate
  • 相关文献

参考文献5

二级参考文献23

  • 1王照谦,杨志强,朱皓,周旭臣,郑晓群,曲新凯,刘晓峰,方唯一.16层CT显示冠状动脉狭窄与导管法造影的对照研究[J].放射学实践,2005,20(3):190-194. 被引量:52
  • 2[1]Windecker S, Maier-Rudolph W, Bonzel T, et al. Interventional cardiology in Europe 1995 [J]. Eur Heart J, 1999, 20(7): 484-495.
  • 3[2]Nieman K, Rensing B J, van Geuns R J, et al. Usefulnessof multislice computed tomography for detecting obstructive coronary artery disease[J]. Am J Cardiol, 2002, 89(8): 913-918.
  • 4[3]Knez A, Becker CR, Leber A, et al. Usefulness of multi slice spiral computed tomography angiography for determination of coronary artery stenoses [J]. Am J Cardiol,2001, 88(10): 1191-1194.
  • 5[4]Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography [J]. Circulation, 2002, 106(16): 2051-2054.
  • 6Gerber TC,Kuzo RS,Lane GE,et al.Image Quality in a Standardized Algorithm for Minimally Invasive Coronary Angiography with Multislice Spiral Computed Tomography[J].J Comput Assist Tomogr,2003,27(1):62-67.
  • 7Flohr T,Ohnesorge B.Heart Rate Adaptive Optimization of Spatial and Temporal Resolution for Electrocardiogram-Gated Multislice Spiral CT of the Heart[J].J Comput Assist Tomogr,2001,25(6):907-923.
  • 8Taylor AJ,Feuerstein I,Wong H,et al.Do Connentional Risk Factions Predict Subclinical Coronary Artery Disease[J].Am Heart J,2001,141(3):463-468.
  • 9Schroeder S,Kopp AF,Baumbach A.Noninvasive Detection and Evaluation of Atherosclerotic Coronary Plaques with Multislice Computed Tomography[J].J Am Coll Cardiol,2001,37(5):1430-1435.
  • 10Nieman K,Cademartiri F,Lemos PA,et al.Reliable Noninvasive Coronary Angiography with for Submillimeter Multislice Spiral Computed Tomography[J].Circulation,2002,106(16):2051-2054.

共引文献223

同被引文献8

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部