摘要
本文研究了用电絮凝法处理受污染源水过程中,电流密度、pH、停留时间对水中COD、细菌和浊度的去除效果的影响,发现电絮凝法对COD、细菌和浊度的去除效果显著;增大电流密度可以加快COD和细菌的去除速度,但使单位能耗增大;pH小于7和大于8有利于COD的去除。
The influence of current density, pH and treatment time on the removal of COD, bacteria and turbidity in polluted natural water was studied when the water was treated in an electrocoagulation process. It was found that the process can reduce the concentrations of COD and bacteria as well as turbidity significantly. The increase of current density can accelerate the removal of COD and bacteria but it increases the power consumption perunit volume water. It is helpful for the removal of COD that the pH of treated water is less than 7 and over 8.
出处
《水处理技术》
CAS
CSCD
1997年第3期169-174,共6页
Technology of Water Treatment
关键词
电絮凝法
细菌
给水处理
COD
制备
electrocoagulation, natural water, organic pollutants, bacteria