期刊文献+

不受TA饱和影响的高压输电线路故障测距算法 被引量:22

Fault Location Algorithm for HV Transmission Lines Immune to Saturation of Current Transformers
在线阅读 下载PDF
导出
摘要 基于线路分布参数模型,考虑电流互感器(TA)饱和或断线导致某一侧电流畸变或不可用的情况,提出了一种输电线路故障测距新算法。该方法通过分析短路序网关系,利用两侧电压和未饱和侧电流,求出不同短路类型下沿线电压和电流的分布,根据过渡阻抗的纯电阻性质,得出当且仅当在故障点处电压和流经过渡电阻的电流的相位相同,由此定位故障点。因此,该测距方法可以不受一侧TA饱和或断线的影响。ATP-EMTP仿真结果也证明了该方法正确、有效。 A new fault location algorithm based on the distributed parameter transmission line model is proposed. The method is not affected by the saturation of current transformers or failures/deformation of current signal at one terminal. The voltage and current profiles along a transmission line are calculated by using sequential network models, the two terminal voltages and the currents from the unsaturated end. Since fault impedance is of pure resistance, the fault can be accurately located at where the Results of ATP-EMTP based simulation prove that the method is correct and efficient.
出处 《电力系统自动化》 EI CSCD 北大核心 2008年第2期67-71,共5页 Automation of Electric Power Systems
关键词 故障测距 线路保护 TA饱和 分布参数 fault location line protection current transformer saturation distributed parameter
  • 相关文献

参考文献16

  • 1束洪春,司大军,葛耀中,陈学允.长输电线路电弧故障定位方法研究[J].电力系统自动化,2000,24(21):27-30. 被引量:20
  • 2全玉生,王晓蓉,杨敏中,严璋,李晓兵,于峥,康林贤,司鲁东,佟科,刘晓峰.工频双端故障测距算法的鲁棒性问题和新算法研究[J].电力系统自动化,2000,24(10):28-32. 被引量:46
  • 3康小宁,索南加乐.求解频域参数方程的双端故障测距原理[J].电力系统自动化,2005,29(10):16-20. 被引量:27
  • 4陈铮,董新洲,罗承沐.电流互感器饱和影响测距精度的一种解决方法[J].电力系统自动化,2002,26(1):39-41. 被引量:11
  • 5KANG Y C, KANG S H, PARK J K, et al. Development and hardware implementation of a compensating algorithm for the secondary current of current transformers. IEE Proceedings: Electric Power Applications, 1996, 143(1): 41-49.
  • 6CHEN K W, GLAD S T. Estimation of the primary current in a saturated transformer// Proceedings of the 30th Conference on Decision and Control: Vol 3, Dec 11-13, 1991, Brighton, UK. Piscataway, NJ, USA: IEEE, 1991: 2363-2365.
  • 7KOJOVIC L A, CUMMINS J C, YU D C. Simplified artificial neural network structure with the current transformer saturation detector provides a good estimation of primary currents// Proceedings of IEEE Power Engineering Society Summer Meeting: Vol 3, Jul 16-20, 2000, Seattle, WA, USA. Piscataway, NJ, USA: IEEE, 2000: 1373-1378.
  • 8ZAMORA I, MINAMBRES J F, MAZON A J, et al. Fault location on two-terminal transmission lines based on voltages. IEE Proceedings: Generation, Transmission and Distribution, 1996, 143(1): 1-6.
  • 9BALCEREK P, IZYKOWSKI J. Improved unsynchronized two- end algorithm for locating faults in power transmission lines// Proceedings of IEEE Bologna Conference on Power Tech: Vol 3, Jun 23-26, 2003, Bologna, Italy. Piscataway, NJ, USA: IEEE, 2003: 6p.
  • 10SAHA M, IZYKOWSKJ J, ROSOLOWSKI E. A two-end method of fault location immune to saturation of current transformers// Proceedings of IEE 8th International Conference on Developments in Power System Protection: Vol 1, Apr 5-18, 2004, Amsterdam, Netherlands. Stevenage, UK,, IEE, 2004: 172-175.

二级参考文献56

共引文献207

同被引文献199

引证文献22

二级引证文献119

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部