期刊文献+

超顺磁氧化铁(SPIO)的MR免疫成像现状及研究进展 被引量:4

暂未订购
导出
出处 《放射学实践》 2008年第1期101-103,共3页 Radiologic Practice
基金 广州市科技攻关基金资助项目(2006J1-C0091)
  • 相关文献

参考文献20

  • 1Gupta H, Weissleder R. Targetedcontrast Agentsin MR Imaging [J]. MR Clin North Am,1996,4(1):171-176.
  • 2Weissleder R,Reimer P,Lee AS,et al. MR Receptor Imaging: Ultrasmall Iron Oxide Particles Targeted to Asialoglyloprotein Receptors[J]. MR,1990,155(6):1161-1167.
  • 3刘新权,景猛,栾彧,姜蓓,刘恩重,侯月玮.不同MR扫描序列对脑内移植SPIO标记神经干细胞大鼠的成像对比研究[J].中国微侵袭神经外科杂志,2004,9(12):560-562. 被引量:6
  • 4刘岘,许乙凯,黄其鎏.不同MR扫描序列在SPIO增强大鼠肝癌模型的对比研究[J].放射学实践,2002,17(5):425-427. 被引量:3
  • 5Schwartz LH, Seltzer SE, Tempany CM, et al. Superparamagnetic Iron Oxide Hepatic MR Imaging: Efficacy and Safety Using Conventional and Fast Spin Echo Pulse[J]. Magn Reson Imaging, 1995,5(5) :566-570.
  • 6Yoshikawa T, Mitchell DG, Hirota S, et al. Gradient- and Spinecho T2-weighted Imaging for SPIO-enhanced Detection and Characterization of Focal Liver Lesion[J]. J Magn Reson Imaging, 2006,23(5) :712-719.
  • 7许乙凯,张嘉宁,刘岘,吴元魁,刘杏元.LAC-HSA-SPIO增强磁共振成像检测大鼠肝癌的实验研究[J].放射学实践,2001,16(6):378-380. 被引量:2
  • 8Yi-Xiang J,Wang Shahid M, Hussain Gabriel P, et al. Superparamagnetic Iron Oxide Contrast Agents:Physicochemical Characteristics and Application in MR Imaging[J]. Eur Radiol, 2001,11 (11) :2319-2331.
  • 9Small WC, Nelson RC, Sherbourne GM,et al. Enhancement Effects of a Hepatocyte Receptor Specific MR Contrast Agent in an Animal Model[J]. J Magn Reson Imaging,1994,4(3) :325-330.
  • 10Reimer P,Bader A,Weissleder R. Preclinical Assessment of Hepatocyte Targeted MR Contrast Agents in Stable Human Liver Cell Cultures[J]. J Magn Reson Imaging, 1998,8(3): 687-692.

二级参考文献38

  • 1张嘉宁,顾为望,许乙凯,吴清洪,袁进,邱添武.大鼠肝癌模型的建立及影像学表现[J].中国实验动物学杂志,1999,9(2):98-101. 被引量:15
  • 2魏光全,宦怡,贺洪德,刘燕丽,楼朝阳,李郁,赵海涛,吴怀玉,葛雅丽.膜相关抗原HAb18抗原基因在荷人肝细胞肝癌裸鼠模型的表达及其意义[J].中华放射学杂志,2006,40(1):10-12. 被引量:3
  • 3[1]Peter F, Sanjay S. Liver-specific MR imaging contrast agents[J]. Radiol Clin North Am, 1998; 36(2): 287-296.
  • 4[2]Oudkerk M, van den Heuvel AG, Wielopolski PA, et al. Hepatic lesions: detection with ferumoxide-enhanced T1-weighted MR imaging [J]. Radiology, 1997; 203(2): 449-456.
  • 5[3]Mayo-Smith WW, Saini S, Slater G, et al. MR contrast material for vascular enhancement: value of superparamagnetic iron oxide [J]. Am J Roentgenol, 1996; 166(1): 73-77.
  • 6[4]van Gansbeke D, Metens TM, Matos C, et al. Effects of AMI-25 on liver vessels and tumors on T1-weighted turbo-field-echo images: implications for tumor characterization [J]. J Magn Reson Imaging, 1997; 7(3): 482-489.
  • 7[5]Shamsi K, Balzer T, Saini S, et al. Superparamagnetic iron oxide particles (SHU555A): evaluation of efficacy in three doses for hepatic MR imaging [J]. Radiology, 1998; 206(2):365-371.
  • 8[6]Price RR, Axel L, Morgan T, et al. Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance task group No. 1 [J]. Med Phys, 1990; 17(2): 287-295.
  • 9[7]Och JG, Clarke GD, Sobol WT, et al. Acceptance testing of magnetic resonance imaging systems: report of AAPM nuclear magnetic resonance task group No. 6 [J]. Med Phys, 1992;19(2): 217-229.
  • 10[8]Kaufman L, Kramer DM, Crooks LE, et al. Measuring signal-to-noise ratios in MR imaging [J]. Radiology, 1989; 173(1): 265-267.

共引文献27

同被引文献80

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部