期刊文献+

城市供水系统两级优化调度的宏观模型研究 被引量:9

Study on the Macroscopic Model of Two-grade Optimization Operation in Urban Water Supply System
原文传递
导出
摘要 在简略阐述净水厂的优化调度模型应针对具体供水系统特征建立的观点后,着重说明了应用前馈神经网络理论建立反映供水系统管网工况的宏观模型新方法,并以沈阳市供水系统为基础提出了两级优化调度数学模型。实例计算与分析结果表明,优化后的调度方案不仅能显著提高各供水二泵站的运行效率,而且可节省电耗约36%。 The viewpoint that the optimization operation model of a waterworks management should be given according to the characteristic of the corresponding urban water supply system is expounded in this paper Then a new method is emphatically introduced of which the macroscopic model reflecting the working status of pipe network can be established by the feedforward neural network Taking Shenyang water supply system as background,the mathematical models of two-grade optimization management are proposed Finally,the results of calculation and analyses show that the management schemes obtained by optimization can obviously raise the operating efficiency of all water supply pump stations,also can reduce the consumption of electricity about 3 6%
作者 郑爽英
出处 《四川联合大学学报(工程科学版)》 EI CAS CSCD 1997年第2期60-68,共9页
关键词 城市 供水系统 优化调度 神经网络 宏观模型 urban water supply,optimization operation,neural network,macroscopic model
  • 相关文献

参考文献6

  • 1赵新华,田一梅,武福平.城市配水系统优化运行的研究[J].中国给水排水,1992,8(3):18-21. 被引量:30
  • 2庄镇泉,神经网络与神经计算机,1994年,18页
  • 3郑爽英,硕士学位论文,1993年
  • 4王训俭,天津大学学报,1988年,3期,1页
  • 5陈跃春,中国给水排水,1986年,2卷,3期,12页
  • 6焦李成,神经网络计算,1983年,35页

二级参考文献1