在消防泵房内有消火栓泵(1用1备),喷淋泵(1用1备),卷帘雨淋泵(1用1备)。用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心,30m^3消防水箱和消防稳压装置分别安装在车库的四面墙。
In the fire water pump room, there are hydrant pumps (one operation, one standby) , sprinkler pumps (one operation, one standby) and rolling shutter drencher pumps (one operation, one standby). Fire equipment, which are used for the foam sprinkler system in underground garage, such as fire alarm valves, foam concentrated tank and chemical dosing pump, etc. are provided in fire equipment centers. Four 30m^3 fire water tanks and fire protection stabilized pressure devices are respectively located at four sides next to the garages.