摘要 Diagnostic neutral beam (DNB) attenuation and charge exchange recombination emission are estimated on EAST tokamak. Approximately 40% of the beam with the energy of 50 keV can reach the plasma centre (r = 0) for the typical parameters of the Experimental Advanced Superconducting Tokamak (EAST) plasma. Emissivities of CVI (n = 8 → 7, 529.0nm) and OVⅢ (n = 10 →9, 607.Ohm) visible charge exchange recombination emissions based on the DNB are estimated. The emissivities of the visible bremsstrahlung emission near this wavelength are also calculated for comparison. The results show that the charge exchange recombination emission is about two orders of magnitude greater than the bremsstrahlung emission. It is theoretically indicated that the ratio of signal of charge exchange recombination spectroscopy to the noise from background bremsstrahlung emission, S/N, is large enough in the EAST tokamak with the typical designed parameters. The present results are helpful for experiment design of charge-exchange recombination spectroscopy based on the DNB in the EAST tokamak. Diagnostic neutral beam (DNB) attenuation and charge exchange recombination emission are estimated on EAST tokamak. Approximately 40% of the beam with the energy of 50 keV can reach the plasma centre (r = 0) for the typical parameters of the Experimental Advanced Superconducting Tokamak (EAST) plasma. Emissivities of CVI (n = 8 → 7, 529.0nm) and OVⅢ (n = 10 →9, 607.Ohm) visible charge exchange recombination emissions based on the DNB are estimated. The emissivities of the visible bremsstrahlung emission near this wavelength are also calculated for comparison. The results show that the charge exchange recombination emission is about two orders of magnitude greater than the bremsstrahlung emission. It is theoretically indicated that the ratio of signal of charge exchange recombination spectroscopy to the noise from background bremsstrahlung emission, S/N, is large enough in the EAST tokamak with the typical designed parameters. The present results are helpful for experiment design of charge-exchange recombination spectroscopy based on the DNB in the EAST tokamak.
出处 《Chinese Physics Letters》 SCIE CAS CSCD 2007年第2期487-489,共3页 中国物理快报(英文版)
基金 Supported by the National Natural Science Foundation of China under Grant Nos 10505008 and 10475078.
关键词 SPECTROSCOPY
  • 相关文献

参考文献9

  • 1Isler R C 1994 Plasma Phys. Control. Fusion 36 171.
  • 2Fonck R J, Darrow D S and Jaehnig K P 1984 Phys. Rev. A 29 3288.
  • 3Synakowski E J, Bell R E, Bundy R Vet al 1995 Phys. Rev. Left. 75 3689.
  • 4Park J and Wurden G Intense Diagnostic Neutral Beam for ITER http://wsx.lanl.gov/publication/LANL-IDNBITER-white-paper.pdf.
  • 5Hu LQ, Wan B N, HuC D et al 2004 Rev. Sci. Instrum. 75 3496.
  • 6Fu P, Song Z Q, Gao G et al 2006 Nucl. Fusion 46 S85.
  • 7Rowan W L and Marmar E S 1997 Rev. Sci. Instrum. 68 300.
  • 8Beu T A 1985 Comput. Phys. Commun. 36 161.
  • 9Whyte D G, Wade M R, D F Finkenthal et al 1997 Nuclear Fusion 38 387.

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部