摘要 目的探讨穿透性角膜移植术后配戴硬性透气性接触镜(rigid gas permeable contact lens,RGPCL)的安全性、有效性及配适特点。方法19例(23眼)穿透性角膜移植术后患者验配RGPCL,其中后表面球面设计2眼,前后表面非球面设计17眼,特殊圆锥角膜设计4眼,配适状态为近似平行配适和三点接触配适。随访时间6~37个月,平均(14.63±3.92)个月。结果戴镜视力达到或超过0.8者14眼(60.87%),0.5以上23眼(100%),显著优于框架眼镜视力(P〈0.01),角膜顶点K值和角膜散光值配戴前分别为(47.18±4.92)D和(6.53±2.26)D,配戴后分别为(45.69±3.04)D及(3.95±1.87)D,均有统计学意义(P〈0.05);角膜内皮细胞密度配戴前为(773±145)个/mm2,配戴后为(742±205)个/mm2,差异无统计学意义,未见有明显角结膜并发症发生。结论穿透性角膜移植术后应用高DK值RGPCL进行屈光重建效果理想、弹性配戴或连续配戴安全,采用非球面设计、特殊后表面设计的RGPCL更易获得理想配适。 Objective To investigate the safety, efficacy and characteristics of rigid gas permeable contact lens (RGPCL) for correction of ammetropia after penetrating keratoplasty. Methods 23 eyes of 19 patients after penetrating keratoplasties were fitted with RGPCL. Among them, 2 had spherical posterior surface designs, 17 had aspherical designs and 4 had special keratoconus designs. The status was in a flat and three points fitting. M1 were followed up for six to thirty-seven months. Results All patients achieved visual acuity over 0.5 and 14 even equal or over 0.8, which was significantly different from the best corrected visual acuity with glasses. After wearing RGP, the K value decreased from 47.18 ± 4.92D to 45.69 ± 3.04D and corneal astigmatism from 6.53 ± 2.26D to 3.95 ± 1.87D ( P 〈 0.05). There were no significant changes in corneal endotheliu. No significant epithelial or corneal complications were observed during the follow up period. Conclusions RGPCL is ideal for refraction reconstruction of ammetropia after penetrating keratoplasty. Both flexible and continuous wearing are safe. It is easier to achieve an ideal fitting state with the aspherical design and special posterior surface design.
出处 《山东大学耳鼻喉眼学报》 CAS 2007年第5期468-470,共3页 Journal of Otolaryngology and Ophthalmology of Shandong University
关键词 角膜移植 硬性透气性接触镜 屈光 重建 Keratoplasty Rigid gas permeable contact lens Refraction Reconstruction
  • 相关文献

参考文献7

二级参考文献43

  • 1Brennan NA, Bruce AS. Esthesiometry as an indicator of corneal health.Optom Vis Sci, 1991;68(9):699-702
  • 2Knoll HA, Williams J. Effects of hydrophilic contact lenses on corneal sensitivity. Am J Optom Arch Am Acad Optom, 1970;47(7):561-563
  • 3Millodot M. Effect of soft lenses on corneal sensitivity. Acta Ophthalmol (Copenh), 1974;52(5):603-608
  • 4Beuerman RW, Rozsa AJ. Threshold and signal detection measurements of the effect of soft contact lenses on corneal sensitivity. Curr Eye Res, 1985;4(6):742-744
  • 5Larke JR, Hirji NK. Some clinically observed phenomena in extended contact lens wear. Br J Ophthalnol, 1979;63(7):475-477
  • 6Hamano H. Topical and systemic influence of wearing contact lenses.Cantacto, 1960;4:41-48
  • 7Ko LS, Tomiyama SK. The influence of contact lens application on the corneal sensitivity. Trans Ophthal Soc Rep China , 1963;2:1-9
  • 8Sabell AG. Ocular changes in contact lens wearers. The Ophthal Optician,1968;8:1051-1057
  • 9Morganroth J, Richman L. Changes in the corneal reflex in patients wearing contact lens. J Pediat Ophthalmol,1969;6:207-208
  • 10Lydon DPM. Effect of rigid contact lens materials on the cornea and tear film of the human eye. PhD dissertation 1986 University of New South Wales.