摘要
本研究的目的在于探讨下颌绞链运动轴点的位置是否恒定以及它是否位于髁突中心点。采用新型的三维下颌运动轨迹描记仪MT-1602测量了14名健康人在4次重复性实验中,下颌小张闭口运动绞链轴点的稳定性及其与髁突的位置关系。结果表明,下颌后退位的小张闭口运动所测得的绞链轴点位置不恒定,存在瞬间绞链轴点。双侧绞链轴点基本均匀地分布于髁突四周,其距髁突中心点的平均距离为8.83±5.65mm。这一结果对临床正确使用架有直接的参考价值。
The aim of this paper was to study the reproducibility of the positions of hinge axis of mandibular retruded small open closed movements, and the positional relationship between the hinge axis and condyles. Fourteen normal students were tested by a six degrees of freedom mandibular movement recorder MT1602 (Germany). The result showed that: the hinge axis could not be exactly repeated and movable instantaneous centers of rotation (ICR) were recorded. These rotation centers distributed almost evenly around the condyles, the mean distance from these rotation centers to condyle centers was about 8.83±5.65mm.
出处
《中华口腔医学杂志》
CAS
CSCD
北大核心
1997年第3期139-142,共4页
Chinese Journal of Stomatology
基金
国家自然科学基金