期刊文献+

酸析—Fenton试剂氧化—混凝法处理制浆废水 被引量:12

Treatment of Pulping Wastewater by Acid Precipitation-FentonReagent Oxidation-Coagulation Process
在线阅读 下载PDF
导出
摘要 用酸析—Fenton试剂氧化—混凝法对自偶氧化清洁制浆废水进行预处理,考察了各种因素对处理效果的影响。最佳处理条件:酸析时的废水pH为3.0;酸析后上层清液无需调节pH,加水稀释至COD为2000mg/L后进行Fenton试剂氧化,H2O2加入量为84.56mmol/L,FeSO4加入量为8.44mmol/L,反应时间60min;混凝时Ca(OH)2加入量为2g/L。最终出水的COD为577.20mg/L(COD去除率为71.14%),色度为36倍,pH为8.60。 Autooxidation cleaner pulping wastewater was pretreated by acid precipitation - Fenton reagent oxidation -coagulation process and the affecting factors were investigated. The optimum conditions are as follows : wastewater pH for acid precipitation 3.0, acid precipitation supernatant pH no adjusted, diluted supernatant COD 2 000 mg/L, H2O2 dosage 84.56 mmoL/L, FeSO4 dosage 8.44 mmol/L, oxidation time 60 min, coagulation Ca (OH)2 dosage 2 g/L. The final effluent COD, chromaticity and pH are 577.20 mg/L, 36 times and 8.6. The removal rate of COD is 71.14%.
出处 《化工环保》 CAS CSCD 北大核心 2007年第4期342-345,共4页 Environmental Protection of Chemical Industry
基金 中国科学院知识创新工程领域前沿项目资助(K2006C2)
关键词 酸析 芬顿试剂 混凝 制浆 废水处理 acid precipitation Fenton reagent coagulation pulping wastewater treatment