摘要
提出了国产超临界600 MW双背压机组凝汽器最佳背压的确定方法,建立了最佳背压的相关计算模型,得出了超临界600 MW双背压机组不同负荷、不同冷却水温和不同循环水泵运行方式下的凝汽器最佳背压。
Optimal backpressure determination of dual condensers for domestic 600 MW supercritical generating unit is proposed. Relative calculation model concerning optimal backpressure is set up and the condenser optimal backpressure for 600 MW supercritical dual backpressure units is reached under different load, different cooling water temperature and different circulating water pump operation mode.
出处
《东北电力技术》
2007年第10期4-6,共3页
Northeast Electric Power Technology
关键词
超临界
双背压
凝汽器
经济运行
Supercritical
Dual backpressure
Condenser
Economic operation