期刊文献+

种植支抗技术压入伸长磨牙的近期疗效观察 被引量:20

Clinical evaluation of implant anchorage for molar intrusion:Report of the short-term results
暂未订购
导出
摘要 目的:应用种植支抗压入伸长磨牙,评价磨牙压入的安全性、有效性,探讨支抗钉的植入部位。方法:选择10例患者,男2例,女8例。年龄25~53岁,平均33岁。上颌磨牙由于对牙长期缺失而伸长,咬合于对颌牙槽嵴黏膜,妨碍牙列修复治疗。利用种植支抗,使用弹性牵引力根向压入伸长的磨牙。结果:10例患者的缺牙区均获得了足够的义齿修复垂直间隙,成功进行种植牙修复。伸长磨牙平均压入3mm,治疗时间平均3.5个月。治疗过程中未发现明显的牙根吸收、牙髓坏死、明显的牙松动。未见牙根尖进入上颌窦。结论:磨牙伸长可通过种植支抗技术予以安全有效地压入,为缺失牙修复创造足够的义齿修复空间。 PURPOSE: The purpose of this study is to evaluate the efficiency and security of self-drilling mini-screw implant anchorage for molar intrusion, to achieve the right position of the mini-screw implant. METHODS: Ten patients with overerupted maxillary molars were selected, aging from 25 to 53 years old, the average age was 33 years old. There were 2 men and 8 women. All the overerupted molars were intruded in gingival direction with mini-screw implants anchorage. RESULTS: The mean intrusive movement of the overerupted maxillary molars was 3 mm, the mean treatment time were 3.5 months.All of the missing teeth were treated by prosthetic treatment. No obvious root resorption, pulp necrosis and tooth loosen were found. CONCLUSIONS: Significant true intrusion of maxillary molars could be obtained by mini-screw implant as bony anchorage.Supported by Shanghai Leading Academic Discipline Project (Grant No.Y0203) and Research Fund of Science and Technology Committee of Shanghai Municipality (Grant No.05B224).
出处 《上海口腔医学》 CAS CSCD 2007年第5期475-479,共5页 Shanghai Journal of Stomatology
基金 上海市重点(优势)学科建设项目(Y0203) 上海市科学技术委员会资助项目(05B224)
关键词 种植支抗 磨牙压人 义齿修复 Implant Anchorage Molar intrusion Prosthetic treatment
  • 相关文献

参考文献23

  • 1Favero L,Brollo P,Bressan E.Orthodontic anchorage with specific fixtures:related study analysis[J].Am J Orthod Dentofacial Orthop,2002,122:84-94.
  • 2朱胜吉,周彦恒,傅民魁,丁鹏.应用种植体支抗正畸治疗的初步临床研究[J].口腔正畸学,2004,11(4):169-173. 被引量:49
  • 3寻春雷,曾祥龙,王兴.微型自攻钛钉种植体支抗压低切牙的初步应用研究[J].口腔正畸学,2004,22(1):29-32. 被引量:75
  • 4Costa A,Raffainl M,Melsen B.Miniscrews as orthodontic anchorage:a preliminary report[J].Int J Adult Orthod Orthog Surg,1998,13:201-209.
  • 5Kanomi R.Mini-implant for orthodontic anchorage[J].J Clin Orthod,1997,31:763-767.
  • 6Wehrbein H,Merz B,Diedrich P,et al.The use of palatal implants for orthodontic anchorage.Design and clinical application of the orthosystem[J].Clin Oral Implants Res,1996,7:410-416.
  • 7Freudenthaler J,Haas R,Bantleon H.Bicortical titanium screws for critical orthodontic anchorage in the mandible:a preliminary report on clinical applications[J].Clin Oral Implants Res,2001,2:358-363.
  • 8Maino B,Mura P,Gianelly A.A retrievable palatal implant for absolute anchorage in orthodontics[J].World J Orthod,2002,3:125-134.
  • 9Nojima K,Komatsu K,Isshiki Y,et al.The use of an osseointegrated implant for orthodontic anchorage to a Class Ⅱ Div 1 malocclusion[J].Bull Tokyo Dent Coll,2001,42:177-183.
  • 10Umemori M,Sugawara J,Mitani H,et al.Skeletal anchorage system for open-bite correction[J].Am J Orthod Dentofacial Orthop,1999,115:166-167.

二级参考文献22

  • 1Creekmore TD, Eklund MK. The possibility of skeletal anchorage. J Clin Orthod 1983; 17 : 266-269.
  • 2Maino BG, Bednar J, Pagin P, Mura P. The spider screw for skeletal anchorage. J Clin Orthod. 2003; 37 (2) : 90-7.
  • 3Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS. Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod. 1984 ;86(2):95-111.
  • 4Wehrbein H, Glatzmaier J, Yildirim M. Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog. Clin Oral Implants Res. 1997Apr;8(2): 131-41.
  • 5Saito S, Sugimoto N, Morohashi T, Ozeki M, Kurabayashi H,Shimizu H, Yamasaki K, Shiba A, Yamada S, Shibasaki Y.Endosseous titanium implants as anchors for mesiodistal tooth movement in the beagle dog. Am J Orthod Dentofacial Orthop.2000 Dec; 118(6): 601-7.
  • 6Roberts WE, Helm FR, Marshall KJ. Rigid endosseous implants for orthodontic and orthopedic anchorage. Angle Orthod. 1989 ; 59: 247-56.
  • 7Odman J, Lekholm U, Jemt T. Osseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patients. Eur J Orthod 1994; 16:187-201.
  • 8Haanaes HR, Stenvik A, Beyer-Olsen ES. The efficacy of twostage titanium implants as orthodontic anchorage in the preprosthodontic correction of third molars in adults-a report of three cases. Eur J Orthod 1991; 13(4): 287-92.
  • 9Higuchi KW, Slack JM. The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement.Int J Oral Maxillofac Implants. 1991; 6:338-44.
  • 10Block MS, Hoffman DR. A new device for absolute anchorage for orthodonics. Am J Orthod Dentofacial Orthop 1995; 107:251-8.

共引文献110

同被引文献205

引证文献20

二级引证文献87

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部