摘要
以深圳某大型电子洁净厂房为例,通过对厂房各分区火灾危险性和上、下技术夹层与生产区作为一个防火分区的可行性进行分析,提出在采取了多种防范及消防保护措施条件下,该工程所存在消防问题的解决办法和措施。
the large electronic clean building in Shenzhen is regarded as a case,fire risk of all the fire compartment in the workshop and the feasibility that top. bottom technique interlayer and producing area taken as one fire compartment are discussed, under the condition that many fire protection measures have been taken.the solution on the problem of fire fighting are put forward.
出处
《消防科学与技术》
CAS
2007年第6期636-640,共5页
Fire Science and Technology
关键词
火灾危险性
防火分区
危险化学品
clean building
fire risk
fire compartment
fire protection measure