摘要 目的研究根管弯曲角度和弯曲半径对根管锉的致损作用。方法采用自制模拟根管弯曲角度和半径的不锈钢管模型,用M4回旋手机(4000rpm)驱动不锈钢K锉,用16:1减速手机(500rpm)驱动Hero642镍钛锉,共4种型号器械各12支,测定锉针在钢管模型中旋转至折断所需时间。结果①根管弯曲半径较小时,根管锉折断所需时间较短(P<0.05);根管弯曲角度较大时,根管锉折断所需时间较短(P<0.05)。②在同一根管模型中,不锈钢K锉直径较细的容易折断(P<0.05);镍钛锉直径较粗的容易折断(P<0.05)。结论①根管弯曲角度越大,根管弯曲半径越小,根管锉折断所需时间越短,即越容易折断;②锉针粗细的变化对不锈钢锉与镍钛锉抗弯曲折断的影响是不同的。 Objective To evaluate the effects of root canal curvature on root canal files fatigue. Methods The fatigue of stainless steel K (SSK) files and Hero642 NiTi files was evaluated with stainless steel curved root canal models. Results The files were fractured more quickly in canal models of the same curvature degree but with smaller curve radius ( P 〈 0.05). The files were fractured more quickly in canal models of the same curve radius but with greater curvature degree ( P 〈 0.05). SSK files with smaller diameter were fractured more easily ( P 〈 0.05). On the contrary, NiTi files with greater diameter were fractured more easily ( P 〈 0.05 ). Conclusion Curve radius and curvature degree had strong influence on the life of files. SSK files with smaller diameter and NiTi files with greater diameter were fractured more easily.
出处 《现代口腔医学杂志》 CAS CSCD 北大核心 2007年第6期630-632,共3页 Journal of Modern Stomatology
基金 国家十五科技攻关计划基金资助项目(2004BA720A23)
关键词 弯曲根管 根管器械 器械断离 Curved root canal Root canal instruments Instruments separation
  • 相关文献

参考文献8

  • 1Youssef H,René S,Geoff B,et al.Dynamic and cyclic fatigue of engine-driven rotary endodontic instruments.J Endod,1999,25(6):434-440.
  • 2Svec TA,Powers JM.A Method to Assess Rotary Nickel -Titanium Files.J Endod,2000,26:517-518.
  • 3Peters OA,Kappeler S,Bucher W,et al.Engine-driven preparation of curved root canals:measuring cyclic fatigue and other physical parameters.Aust Endod J,2002,28(1):11-17.
  • 4袁理,岳林,王嘉德.Hero642镍钛锉断裂损伤的形态研究[J].实用口腔医学杂志,2006,22(5):604-607. 被引量:20
  • 5郑玉峰,李超,黄陈,赵连城.Smart~镍钛根管器械的扭转性能与旋转疲劳断裂行为研究[J].实用口腔医学杂志,2005,21(2):217-220. 被引量:10
  • 6袁理,岳林,王嘉德.不锈钢K型根管锉模拟根管预备的三维有限元应力分析[J].中华口腔医学杂志,2007,42(6):346-348. 被引量:7
  • 7Zelada G,Varela P,Martin B,et al.Theeffect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments.J Endod,2002,28(7):540-542.
  • 8Gambarini G.Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low-and high-torque endodontic motors.J Endod.2001,27(12):772-774.

二级参考文献25

共引文献33

同被引文献20

引证文献2

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部