目的:探讨改良传统的T管胆道造影方法。方法:使用两种加入地塞米松和利多卡因的两种不同浓度的造影剂,取不同体位给病人造影,另取一传统方法造影组对照。结果:改良型T管造影显像优秀率100%,术中患者不适率5%,诊断符合率86%;传统法T管造影显像优秀率70%,术中患者不适率27%,诊断符合率57%。结论:改良型T管造影可明显提高显像优秀率、诊断符合率,降低术中患者不适率。
Object: To probe into ameliorating "T" tube cholangiographic methods.Method: One group of patients were treated with the ameliorated method: after taking two different doses of dexmathesone or lidocane,they were radiographied in different body postures via "T" tube,another group were radiographied following the traditional method for comparison.Results: In the ameliorated method,100% of patients had showed an excellent opacification,5% had some uncomfortable feeling,86% had got a correct diagnosis whereas in the traditional method group,70% showed an excellent opacification,and 27% had uncomfortable feedings,only 57% had got a correct diagnosis.Conclusion: The ameliorated "T" tube cholangiography can significantly enhance the efficiency of cholangiography,improve the diagnosis and reduce patients' uncomfortable feedings.
出处
《影像技术》
CAS
2007年第5期61-62,共2页
Image Technology
关键词
改良
T管
胆道造影
Ameliorate
"T" tube
cholangiography