摘要 对于实际的3D-CT成像系统,射线源焦点和物体旋转轴中心的位置不能直接测量,如何采取简单易行的方法精确测量二者之间的距离(即系统焦距)成为一项工程技术难点.通过双圆目标体二次成像获得射线数字成像(DR,Digital Radiography)图像,对各DR图像进行自相关处理,获得双圆投影中心距,再通过解析方法求解出系统焦距值.实验结果表明,测量精度达到了实际扫描系统的重建要求.该方法实现简单,具有较强的抗噪能力,可实现自动测量. In the three dimensional computed tomography imaging system, it is impossible to measure the X-ray focus to object-rotating-axis distance (FOD) by direct means, so how to obtain the value of FOD with simple and feasible method is an involved engineering problem. Through acquiring the digital radiography (DR) images of the double-circled object at two imaging positions, the auto-correlation operation was executed, so as to get distance of the two circles' projection center. Then through solving equations, the value of FOD was finally obtained. Experiment results prove that the accuracy of this method can satisfy the requirements of the practical scanning system. This testing method is also easy to realize and of high anti-noise ability. Furthermore, it can be realized automatically by software.
出处 《北京航空航天大学学报》 EI CAS CSCD 北大核心 2007年第10期1216-1219,共4页 Journal of Beijing University of Aeronautics and Astronautics
基金 国家自然科学基金资助项目(60402042) 北京市科技新星资助项目(2005A14)
关键词 焦点焦距 图像自相关 射线检测 focus to object-rotating-axis distance (FOD) image auto-correlation X-ray testing
  • 相关文献

参考文献5

  • 1Feldcamp L A, Davis L C, Kress J W. Practical cone-beam algorithm[J]. J Opt Soc Am Al,1984:612 - 619
  • 2倪建平,李政,白宏涛,刘亚强,程建平,高文焕,康克军.微焦点X射线成像系统扫描参数测量及投影图像校正研究[J].核电子学与探测技术,2001,21(3):165-168. 被引量:3
  • 3杨民.基于面阵探测器的多模式工业CT技术研究[D].北京航空航天大学,2004.
  • 4Jiang Hangyi. Techniques to improve the accuracy and to reduce the variance in noise power spectrum measurement[J]. IEEE Transactions on Biomedical Engineering, 2002, 49 ( 11 ) : 1270 - 1278
  • 5Van Metter Richard, Yorkston John. Factors influencing image quality in digital radiographic system[J]. Proc SPIE Int Soc Opt Eng, 2001, 4320:244-255

二级参考文献5

  • 1Kinahan PE,et al.Attenuation correction for a combined 3D PET CT scanner[].Medical Physics.1998
  • 2Hsieh J,et al.An iterative approach to the beam hardening correction in cone beam CT[].Medical Physics.2000
  • 3Gronenschild E.Correction for geometric image distortion in the X-ray imaging chain: Local technique versus global technique[].Medical Physics.1999
  • 4Viskoe A.Computed tomography post acquisition data correction for system alignment errors[].IEEE Transactions on Instrumentation and Measurement.1999
  • 5Fahring R,et al.Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII : Image-based correction of gantry motion nonidealities[].Medical Physics.2000

共引文献3

同被引文献9

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部