摘要
采用高效液相色谱法进行含量测定。色谱柱为Agilent Hypersil C18(25cm×4.6mm,5μm),以0.005mol/L四丁基氢氧化铵溶液(取40%四丁基氢氧化铵6.6mL,加水1800mL,用磷酸调pH至4.0,再加水稀释至2000mL)-乙腈(720∶280)为流动相;检测波长为220nm。头孢哌酮钠、舒巴坦钠两种成分的回收率分别为100.9%、100.6%,RSD分别为0.31%、0.51%(n=6)。该方法简便,结果准确可靠。
To establish HPLC for determination of contents in cefoperazone sodium and sulbactam sodium for injection. The analytical column was Agilent Hypersil Cm column (25 cm×4. 6mm, 5μm). The mobile phase was consisted of 0. 005 mol/L tetrabutyl ammonium hydroxide (take 40% tetrabutyl ammonium hydroxides , add 1 800 mL water, adjusted to pH 4.0 with phosphoric acid,eventually use water to dilute till 2 000 mL)and acetonitrile (720:280). Detection wavelength was 220 nm. The average recovery (n=6) were 100. 9% for cefoperazone sodium (RSD=-0. 31%) and 100. 6% for sulbactam sodium (RSD=0. 51%). The method was simple, accurate and reliable.
出处
《河北化工》
2007年第10期74-75,共2页
Hebei Chemical Industry