脉冲多普勒超声心动图估测中心动脉压与心导管测量的相关性研究 被引量:1

Correlation between pulse Doppler echocardiography-estimated and catheter-measured central aortic pressure
暂未订购
导出
摘要 目的探讨脉冲多普勒超声心动图技术估测中心动脉压的应用价值。方法采用脉冲多普勒超声心动图探测35例行心导管术的患者术前主动脉瓣瓣上血流,测量加速时间(AcT)、左室射血时间(LVET)、左室射血前期(PEP),将测得的数据与心导管测得的相应数值,收缩压(SBP)、舒张压(DBP)、脉压(PP)、平均动脉压(MBP)作相关分析。结果AcT/LVET与MBP呈正相关(P<0.01),AcT/PEP与MBP呈负相关(P<0.01)。结论脉冲多普勒超声心动图技术在无创估测中心动脉压上有重要的应用价值。 Objective To explore the value of pulse Doppler echoeardiography in estimation of central aortic pressure. Methods Thirty - five patients were studied. Upper aortic valve flow of patients were measured by pulse wave Doppler imaging. Accelerate time(AcT) ,left ventrieular ejection time(LVET),left ventrieular ejection prophase(PEP) were estimated. The correlation between the numerical values and catheter-measured CAP was studied. Results There was a good relation between Doppler and catheter. AcT/ LVET had a positive correlation with MBP. AcT/PEP had a negative correlation with MBP. Conclusion Ptdse Doppler echocardiography is a noninvasive and valuable method for estimating CAP.
出处 《临床超声医学杂志》 2007年第9期516-518,共3页 Journal of Clinical Ultrasound in Medicine
关键词 超声心动描记术 中心动脉压 Echocardiography Central aortic pressure
  • 相关文献

参考文献9

  • 1Kelly PiP, Millasseau SC, Bitter JM, et al. Vasoacfive drugs influence aortic augmentation index independently of pulse wave velocity in healthy men. Hypertension, 2001,37 : 1429 - 1433.
  • 2Hirala K, Vlachopoulos C, Adji A, et al. Benefits from angiotensin- converting enzyme inhibitor "beyond blood pressure lowering": beyond blood pressure or beyond the brachial artery? J Hypertens,2005,23(3) : 551 - 556. Erratum in: J Hypertens, 2005 ,23(3) :903 - 904.
  • 3汤池,杨国胜,席涛.无创连续血压测量方法的研究进展[J].医疗卫生装备,2004,25(10):26-27. 被引量:16
  • 4London GM, Asmar RG, O' Rourke MF, et al. Mechanisms of selective systolic blood pressure reduction after a low - dose combination of perindopril/indapa- mide in hypertensive subjects: comparison with atenolol. J Am Coll Carchol,2004,43( 1 ) :92 - 99.
  • 5Roman MJ, Kizer JR, AU T, et al. Central blood pressure better predicts cardiovascular events than does peripheral blood pressure :the Strong Heart Study. Circulation,2005,112( Suppl Ⅱ ) :770 - 778.
  • 6Henneman E, Henneman PL. Intricacies of blood pressure measurement: reexamining the rituals. Heart Lung, 1989,18(3) :263 - 271.
  • 7Bridges EJ. The systemic cilculation. In: Woods SL, Molzcr S, Sivarajan -Froelicher KS, eds. Cardiac Nursing. 4thed. Philadelphia, Pa: JB Lippincott, 1999.51 - 71.
  • 8Marino PL. The ICU Book. Philadelphia,Pa: Lea & Febiger, 1998.
  • 9Grossman W. Pressure measurement. In: Grossman W. Baim D, eds. Cardiac Catheterization, Angiography and Intervention. 5th ed. Baltimore, Md: Williams & Wilkins, 1996. 125 - 142.

二级参考文献21

  • 1陆渭明,李和平,蒋正尧,崔鲁宁,陶上乘,张冬梅,涂继善,缑东元.对利用脉搏波传播速度间接测量血压时主要影响因素的研究[J].中国生物医学工程学报,1995,14(1):89-93. 被引量:14
  • 2胡章和,李震,田孝坤.孕妇血压与其脉搏波的相关性研究与应用[J].生物医学工程学杂志,1995,12(2):162-164. 被引量:11
  • 3罗志昌,张松,杨文鸣,杨子彬.脉搏波波形特征信息的研究[J].北京工业大学学报,1996,22(1):71-79. 被引量:121
  • 4Nakagawara M,Yamakoshi K.A portable instrument for non-inva sive monitoring of beat-by-beat cardiovascular haemodynamic pa rameters based on the volume- compensation and electrical-ad mittance method[J].Med&amp;Biol&amp;Comput,2000,38( 1 ): 17~25
  • 5Maguire M,Ward T, Markham C,et al.A comparative study in the use of brachial photoplethysmography and the QRS complex as timing references in determination of pulse transit time[C].Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd
  • 6Lehmann ED.Where is the evidence that radial artery tonometry can be used with a generalised transfer function to accurately and non-invasively predict central aortic blood pressure?[J].Journal Of Human Hypertension, 2001,15(2):145~146
  • 7Yamakoshi K,Shimazu H,Togawa T.Indirect measurement of instan taneous arterial blood pressure in the human finger by the vascu lar unloading technique[J].IEEE Transactions on Biomedical Engi neering, 1980,27(3): 150~155
  • 8Tanaka S,Yamakoshi K.Ambulatory instrument for monitoring indi rect beat-to-beat blood pressure in superficial temporal artery us ing volume-compensation method[J].Med&amp;Biol&amp;Comput,1996, 34(6):441-447
  • 9Imholz BP,Wieling W,van Montfrans GA,et al.Fifteen years expe rience with finger arterial pressure monitoring:assessment of the technology[J].Cardiovascular Research,1998,38(3):605-616
  • 10Gribbin B,Steptoo A,Sleight P.Pulse wave velocity as a measure of blood pressure change[J].Psychophysiology, 1976,13(1):86-90

共引文献15

同被引文献22

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部